8.0 Common faults and handling methods 

 
8.1 Fault analysis and processing form 

Malfunction 

Analysis 

Methods 

 
 
Machine doesn

work 

Did not open the power 
switch 

Please turn on the power 
switch 

Power cord broken 

Check and connect 

Overload protector jumps off  Check and press reset 
Electronic centrifugal 
switch, capacitor damage 

Contact the manufacturer 
for replacement 

Relay damage

 

 

Contact the manufacturer 
for replacement 

Power switch damage 
 

Contact the manufacturer 
for replacement 

 
 
Brush motor 
doesn

t work 

 

The switch damaged

 

Replace 

Brush motor damage and its 
wiring damage 

Contact the manufacturer 

Relay damage 

Contact the manufacturer 

 
Suction motor 
doesn

t work 

Switch damage 

Replace 

Suction motor and its 
circuit damage 

Contact the manufacturer 

Suction motor cabon brush 
badly worn 

Contact the manufacturer 

Relay damage 

Contact the manufacturer 

 

The solution has little or no 

flow

 

The ball valve is opened too small or 
closed

 

Adjust flow switch 
 

The set of flow switch is 
too small or the flow switch 
is off 

Adjust flow switch 

Solution hose or filter 
clogged 

Rinse the water pipe or 
strainer with clean water 

Drain solenoid valve is 
blocked 

Disassemble the discharge 
solenoid valve and clean 
it 

 
 
Poor water 
absorption 

Sewage tank full 

Drain the sewage tank 

The plug of the drain pipe 
has come loose 

Tighten the drain plug 
 

Water scraper assembly 
blocked 

Clean the water scraper 

Water wipers wear out 

Turn to use or replace 

The scraper is not in the 
correct position 

Adjust the height of the 
scraper and the ground 

Summary of Contents for 520BM

Page 1: ...520BM Battery type Hand push type Automatic Floor Scrubber Manual Please read this manual carefully before using the product ...

Page 2: ...ll the design control methods and functions of the washing machine The first use of the washing machine the operator should put it in an open area to understand its various functions The start of any operation work first check the washing machine and its parts in general and in the operation of the state If the working state of the washing machine is not normal the equipment cannot be used The ope...

Page 3: ...Parameter Rated voltage 220V Working width 510mm Suction width 760mm The efficiency 2000 h Brush 510mm Brush speed 150rpm Brush motor 750W Brush pressure 30kg Suction motor 600W Vacuum 180mbar Turning radius 600mm Clean water tank 50L Sewage tank 55L Noise level 65dB Batteries weight 70 kg Machine weight without batteries 75kg The length of the wire 25M ...

Page 4: ...he suction 02 Hang the squeegee on the fixed palm 04 and tighten the two knobs Connect the end of the suction hose 05 to the suction rack 5 2 Installation of brush hundred cleaning pad and needle holder Step on the foot pedal 06 and lean against the left position and the nose of the front end will follow Place the brush 07 or hundred cleaning pad and needle holder under the center of the head cove...

Page 5: ... end of the YL815 scrubber clean water tank 12 is provided with a water injection port 13 which can be directly filled with water According to the situation of dirt on the ground inject clean water and appropriate amount of cleaner into the water tank Warning If the used cleaner has too much foam it means that the cleaner is not suitable for the use of automatic floor washer Please replace the cle...

Page 6: ...cessively to start the machine normally Adjust the amount of water as required 14 7 2 Warning and operation instructions of full water in sewage tank When the sewage level in the sewage tank is close to the maximum limit water level the buoy 15 will jump up and block the air outlet 17 so that the vacuum motor cannot work properly and make different noises The suction trap will drain the water off ...

Page 7: ... t work Switch damage Replace Suction motor and its circuit damage Contact the manufacturer Suction motor cabon brush badly worn Contact the manufacturer Relay damage Contact the manufacturer The solution has little or no flow The ball valve is opened too small or closed Adjust flow switch The set of flow switch is too small or the flow switch is off Adjust flow switch Solution hose or filter clog...

Page 8: ...ntenance and repair 1 Remove the pin holder brush tray and wipe with a specific cleaner 2 Drain the sump and rinse with clean water Check the sewage tank for debris Remove it immediately In addition the remaining solvent in the water tank should be discharged clean twist open water discharge plug 21 discharge 3 Lift the wiper assembly off the floor and wipe the wiper strip with a wet towel 4 Remov...

Page 9: ...ease contact the manufacturer of automatic floor washer 2 Check the motor carbon brush every 250 hours after use If the carbon brush wear seriously please contact the manufacturer to replace 9 4 Machine storage 1 Store indoors and in a dry place 2 Keep it upright 3 Lift the brush tray off the ground 4 Lift the wiper assembly off the ground 5 If the storage place is extremely cold the machine shoul...

Page 10: ...10 0 Explosive view ...

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...tch 1 18 4X10 head self tapping screw 2 19 Delay 1 20 Power lock 1 21 key switch 2 22 panel 1 23 3X10 pan head self tapping screw 6 24 Overload protector 1 25 Power indicator light 1 26 M8X45 cylinder head with hexagon screw 2 27 Sewage tank 1 Water absorbing capacity 55L 28 Suction pipe 1 29 Movable buckle 1 30 Movable buckle gasket 2 31 Movable buckle spring 2 32 M5X20 pan head screw with nuts 2...

Page 17: ...fting glove accessories 1 61 M8X25 cylinder head hexagon screw 1 62 lifting the glove end cover 1 63 Lift the glove shaft sleeve 1 64 M8X60 external hexagon screw with nut 1 65 M6X16 cylinder head hexagon screw 3 66 Lifting handle holder 1 67 water regulating lever 1 68 Water regulating handle 1 69 cotter 1 70 24X3 5 O circle 2 71 adjustment lever connection 1 72 M4X12 pan head screw 2 73 Water va...

Page 18: ...n screw 8 103 M8X25 countersunk head screw 3 104 18X12PVC flexible rubber hose 2 105 13 20 Hose hoops 4 106 solenoid valve 1 107 Three blades 1 108 Cant meson 3 109 M6X40 cylinder head hexagon screw with nuts 3 110 edge wheel 3 111 tension pin 1 112 stents active cooper bush 7 113 M8X30 outer hexagonal screw with nuts 5 114 bush lifting stents 1 115 M8X20 outer hexagonal screw 4 116 the frame 1 11...

Page 19: ...ort 2 144 Suction stent main body 1 145 Suction stent height adjustable wheel 2 146 M6X25 cylinder head hexagon screw with nuts 6 147 suction stent back clamp 1 148 clamp buckle assembly 1 149 M4X6 half round head screw with nuts 4 150 strip after the water suction stent 1 151 strip before the water suction stent 1 152 suction stent front clamp 1 153 M12 nuts 2 154 M6X40 cylinder head hexagon scre...

Reviews: