5
B4600 series Battery-Powered Tools (HK1189
)
DRIVE UNIT:
Brushless direct current motor
WEIGHT:
3.9 lbs (1.7 kg) without battery or nose piece
4.4 lbs (2.0 kg) with battery
STROKE:
.985 in. (2.5 cm)
PULL CAPACITY:
4496 lb
BATTERY AND CHARGER:
18V battery; 100-240V/50-60Hz charger
Battery rated for 2.1 Ah
Optimum operating temperature range: 50-122°F (10°-50°C)
Full charging takes approximately 40 minutes. (Charging times
may vary according to the remaining capacity and the battery
temperature.)
One battery can be charged approximately 1000 times.
One fully charged battery will install approximately 500
fasteners. Number of fastener installations may vary based
on the age of the battery and the size and strength of the
fastener.
The tool battery has a display showing battery life in percent.
Press the button in the display to activate the green LED lights
for approx. 5 seconds, and use the table at right to determine
capacity.
Principle of Operation
Description
The B4600 tool is designed to install up to -08 MGL and
up to -06 MG and is compatible with standard “L” version
noses.
The B4600S tool is designed to install up to -06 BB
and -06 BR fasteners, and is compatible with standard
aerospace noses.
Specially designed for low-volume production
environments, these installation tools are portable, with
no hoses or cords. Batteries are easily replaced and/or
recharged when they have been depleted of life.
11.22
(28)
2.99
(7.0)
1.06
(2.3)
2.68
(6.8)
11.42
(29)
1.5
(3.8)
4.45
(11.3)
inches
(cm)
3.08
(7.8)
2.75
(6.99)
The nose assembly is placed over the end of the fastener
until the tool’s anvil bottoms on the fastener. When
the trigger is pressed, the drive unit draws the collet
rearward and breaks the pintail of the fastener in tension.
After the fastener pintail is broken, the trigger must be
released, at which point the drive unit returns the collet
forward. The tool is then ready for the next fastener.
Specifications
INDICATOR
EXPLANATION
Constant GREEN Battery is fully charged.
Flashing GREEN Battery is charging.
Constant RED Charging temperature error (Battery too
hot or too cold)
Flashing RED
Battery is defective, or wrong battery
BATTERY CHARGER FUNCTION LIGHTS
BATTERY FUNCTION LIGHTS
INDICATOR
EXPLANATION
Battery is fully charged.
Battery is at 80% capacity.
Battery is at 60% capacity.
Battery is at 40% capacity.
Battery is at 20% capacity.