Relay Output Selection

Relay channels CH6-16 can be configured to use either the normally open or normally closed
contact. Placing a link in position A selects the former, in position B, the latter.

Channel 6
Channel 7
Channel 8
Channel 9
Channel 10
Channel 11

Link 9
Link 6
Link 3
Link 12
Link 10
Link 7

Channel 12
Channel 13
Channel 14
Channel 15
Channel 16

Link 4
Link 11
Link 8
Link 5
Link 2

Output Connector (PL2) Pin Assignments

The Output Connector is a 37-way D-Type female connector with the following pin-out:

Pin No.

Function

Pin No.

Function

19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1

Relay 16 NC/NO
Relay 15 NC/NO
Relay 14 NC/NO
Relay 13 NC/NO
Relay 12 NC/NO
Relay 11 NC/NO
Relay 10 NC/NO
Relay 9 NC/NO
Relay 8 NC/NO
Relay 7 NC/NO
Relay 6 NC/NO
Relay 5 NC
Relay 5 common
Relay 4 NC
Relay 3 NC
Relay 3 common
Relay 2 NO
Relay 1 NC
Relay 1 common

37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20

Relay 16 common
Relay 15 common
Relay 14 common
Relay 13 common
Relay 12 common
Relay 11 common
Relay 10 common
Relay 9 common
Relay 8 common
Relay 7 common
Relay 6 common
Relay 5 NO
Relay 4 NO
Relay 4 common
Relay 3 NO
Relay 2 NC
Relay 2 common
Relay 1 NO

Summary of Contents for ST-RELAY16

Page 1: ...01 824 511 Fax 08001 824 512 Netherlands Gratis 0800 Nummer Tel 0800 0221136 Fax 0800 0221148 Italy Numero Verde Tel 0800 790841 Fax 0800 780841 Whilst Arcom s sales team is always available to assist you in making your decision the final choice of boards or systems is solely and wholly the responsibility of the buyer Arcom s entire liability in respect of the boards or systems is as set out in Ar...

Page 2: ...Introduction 3 Features 3 Operation 4 I O Map 4 Links 5 Address Selection 5 Relay Output Selection 6 Output Connector PL2 Pin Assignments 6 Circuit Diagrams 7 Revision History Manual PCB Comments Iss A Iss B V1 Iss1 V1 Iss1 980529 000831 First release of manual ECO2911 ...

Page 3: ... board Features 8 changeover relays with a power switching rating of 60W resistive load Switching voltage upto 48v DC and switching currents up to 1 0A Output status readback register Relay drivers disabled on power up and reset Both normally closed and or normally open contacts are available at the output connector RC snubber networks on all outputs STEbus interface ANSI IEEE Std 1000 1987 Board ...

Page 4: ...03H to enable both groups For system initialisation it is recommended that the output registers are written with the required relay states before the enable bits are set I O Map Address Function Register Name Bit Function Base W Relay Output CH1 8 Bit 0 7 1 ON 0 OFF Base R Relay Status CH1 8 Bit 0 7 1 ON 0 OFF Base 1 W Relay Output CH9 16 Bit 0 7 1 OFF 0 ON Base 1 R Relay Status CH9 16 Bit 0 7 1 O...

Page 5: ... 6 for the default address Inserting a jumper selects logic 0 for the particular address bit Default Link Position Address is 360h User Configuration Record PL2 LED1 LK 11 A B LK12 A B B A A B LK 8 LK 10 LK5 A B B A LK 7 LK2 A B A B LK 4 LK9 LK6 LK3 A B A B A B LK 1 A B C D E F G H PL1 PL2 LED1 LK11 A B LK12 A B B A A B LK8 LK10 LK5 A B B A LK7 LK 2 A B A B LK4 LK9 LK6 LK3 A B A B A B LK1 A B C D ...

Page 6: ... a 37 way D Type female connector with the following pin out Pin No Function Pin No Function 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Relay 16 NC NO Relay 15 NC NO Relay 14 NC NO Relay 13 NC NO Relay 12 NC NO Relay 11 NC NO Relay 10 NC NO Relay 9 NC NO Relay 8 NC NO Relay 7 NC NO Relay 6 NC NO Relay 5 NC Relay 5 common Relay 4 NC Relay 3 NC Relay 3 common Relay 2 NO Relay 1 NC Relay 1 commo...

Page 7: ...CONTROL SYSTEMS J585 ST RELAY16 2192 10475 000 000 Page 7 Circuit Diagrams ...

Page 8: ...CONTROL SYSTEMS J585 ST RELAY16 2192 10475 000 000 Page 8 ...

Page 9: ...CONTROL SYSTEMS J585 ST RELAY16 2192 10475 000 000 Page 9 ...

Reviews: