background image

User Manual

GB

DMX control interface » 

LSDMX

WARNING! Before carrying out any operations with the unit, carefully read this instruction manual and keep it with cure for future 

reference. It contains important information about the installation, usage and maintenance of the unit.

The information provided in this manual has been carefully checked. However Music & Lights is not responsible for any possible inaccuracy.

Design and specifications are subject to change without notice.

For further information, please contact our Service Center: tel. +39 0771 72190   fax +39 0771 721955 - [email protected]

Rev003  - 11/11  ©2011 Music & Lights S.r.l.   -   Italy   -   www.musiclights.it

power 

adapter

3 Pin signal wires

DMX512 Console

AC110V~230V

AC110V~230V

DC12V~24V

DIP Switch

DMX512IN DMX512OUT

DMX512OUT

Ch1

com V+ V-

-

+

Ch2

Ch3

R1
R2
R3

power 

adapter

AC110V~230V

DC12V~24V

DIP Switch

DMX512IN DMX512OUT

Ch1

com V+ V-

Ch2

Ch3

R1
R2
R3

power 

adapter

AC110V~230V

DC12V~24V

DIP Switch

DMX512IN DMX512OUT

Ch1

com V+ V-

Ch2

Ch3

R1
R2
R3

3 Pin signal wires

3 Pin signal wires

INPUT

OUTPUT

V-

V+

COM

CH1

CH2

CH3

Nero

Rosso

Power

Verde

Blue

General instruction

•  The products referred to in this manual conform to the European Community Directives 

and  are  therefore  marked  with  .  •  Supply  voltage  of  this  product  is  DC12V~24V; 

never  connect  to  AC220V.  Leave  servicing  to  skilled  personnel  only.  Never  make  any 

modifications on the unit not described in this instruction manual, otherwise you will risk 

an electric shock. •  Connection of the power adapter must be made to a power supply 

system fitted with efficient earthing (Class I appliance according to standard EN 60598-

1).  It  is,  moreover,  recommended  to  protect  the  supply  lines  of  the  units  from  indirect 

contact  and/or  shorting  to  earth  by  using  appropriately  sized  residual  current  devices. 

•  The connection to the main network of electric distribution must be carried out by a 

qualified  electrical  installer.  Check  that  the  voltage  correspond  to  those  for  which  the 

unit is designed as given on the electrical data label. •  This unit is not for home use, only 

professional applications. •  Never use the fixture under the following conditions: - in place 

subject to excessive humidity; - in places subject to vibrations or bumps; - in places with 

a temperature of over 60°C or -20°C. •  Make certain that no inflammable liquids, water or 

metal objects enter the fixture. • Do not dismantle or modify the fixture. •  All work must 

always  be  carried  out  by  qualified  technical  personnel.  Contact  the  nearest  sales  point 

foran inspection or contact  the manufacturer directly. •  If the unit is to be put out of 

operation definitively, take it to a local recycling plant for a disposal which is not harmful 

to the environment. 

Warnings and installation precautions

•    When  carrying  out  any  work,  always  comply  scrupulously  with  all  the  regulations 

(particularly regarding safety) currently in force in the country in which the fixture’s being 

used.

 •  If this device will be operated in any way different to the one described in this 

manual, it may suffer damage and the guarantee becomes void. Furthermore, any other 

operation may lead to dangers like short circuit, burns, electric shock, etc. •  Before starting 

any maintenance work or cleaning the projector, cut off power from the main supply. • Do 

not touch the power cables if your hands are wet. •   Keep any inflammable material at a 

safe distance from the fixture. •  When cleaning unit, please do not use solvents such as 
acetone or alcohol, since they may damage the of the unit outer finish

Description and technical specifications

DMX control interface for LEDSTRIP.

•  Manual mode through dip-switches to control colour changes and automatic programs.

•  DMX channel selection to link the interface to external DMX consoles.

•  3 channels operating mode.

•  Input connections: XLR-3p plug, RJ45 socket.

•  Output connections: XLR-3p socket, RJ45 socket.

•  Max output of current: 3x4A

•  Max power: 3x48W (144W)
•  Dimensions: 165x75x40 mm

Installation

The LSDMX should be placed on a non-flammable flat surface in any orientation and fixed 
by the two screws. There are two mounting holes on the housing.

Linking

After making the connection LSDMX supply (DC12V~ 24V), connect the unit with other 

devices in the manner shown in diagram below. The LSDMX is equipped with two types of 

connectors: 3-pole XLR and RJ45.

Functions and settings

LSDMX has a basic control panel consists of a DIP-switch (fig.2). Each individual switch has 

a number (DIP switch [1] a [10]).

Switch number

Fig.2

Fig.1

Manual mode

To set the manual mode is necessary to position the DIP-switch [8] & [9]  to ”OFF” and  the 

DIP-switch [10] to ”ON”. DIP-switch [1 - 7] allow the setting of colors as shown in the fol

-

lowing table:

DIP-switch

1

2

3

4

5

6

7

8

9

10

Red

Green

Blue Yellow Purple Cyan

White

OFF

OFF

ON

DIP-switch

1 2 3 4 5 6 7

8

9

10

SPEED (Slow - Fast)

SHOW

(Seven-color jumpy

changing effect)

SHOW

(Seven-color gradual

changing effect)

ON

NOTE  - When  the  DIP-switch  set  to “ON”,  the  priority  is  given  to  the  DIP-switches  with 

higher value.

Automatic mode

To set the automatic mode is necessary to position the DIP-switch [10] to ”ON”. Other set

-

tings are shown in the following table:

•  DIP-switch [8] to “ON” shows the seven-color jumpy changing effect.

•  DIP-switch [9] to “ON” shows the seven-color gradual changing effect.

Every effect has different speeds from slow to fast (setting DIP-switch [1 - 7] to “ON”). 

DMX mode

To set the DMX mode is necessary to position the DIP-switch [10] to ”OFF”. 

As DMX interface, the unit has 3 poles XLR contacts and RJ45 connectors. The following 

table shows the operating mode and DMX value. 

The easiest way is to start from the highest possible place value and to add the smaller 

values until the start address will result.

Example: 

Address 24: switch n° 4 and 5 set 

to ON

1

2

4

8

16

32

64

128

256

Fig.3

The address is set to start as a binary number by means of DIP-switch n° 1 - 9. Thus, it ap

-

pears the addition values of DIP-switches positioned to ON.

Channel

Function 

DMX value

1

RED  0-100%

000 - 255

2

GREEN 0-100%

000 - 255

3

BLUE 0-100%

000 - 255