Architectural Acoustics Quadra 15P User Manual Download Page 2

Intended to alert the user to the presence of uninsulated “dangerous voltage”  within the product’s
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

Intended to alert the user of the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the product.

C

CA

AU

UT

TIIO

ON

N::

Risk of electrical shock — DO NOT OPEN!

C

CA

AU

UT

TIIO

ON

N::

To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside.

Refer servicing to qualified service personnel.

W

WA

AR

RN

NIIN

NG

G::

To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture.

Before using this appliance, read the operating guide for further warnings.

Este símbolo tiene el propósito, de alertar al usuario de la presencia de “(voltaje) peligroso” sin
aislamiento dentro de la caja del producto y que puede tener una magnitud suficiente como para
constituir riesgo de descarga eléctrica.

Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la
operación y mantenimiento en la información que viene con el producto.

P

PR

RE

EC

CA

AU

UC

CIIO

ON

N::

Riesgo de descarga eléctrica ¡NO ABRIR!

P

PR

RE

EC

CA

AU

UC

CIIO

ON

N::

Para disminuír el riesgo de descarga eléctrica, no abra la cubierta. No hay piezas útiles

dentro. Deje todo mantenimiento en manos del personal técnico cualificado.

A

AD

DV

VE

ER

RT

TE

EN

NC

CIIA

A::

Para evitar descargas eléctricas o peligro de incendio, no deje expuesto a la lluvia o

humedad este aparato Antes de usar este aparato, Iea más advertencias en la guía de operación.

Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur la présence d’une tension dangereuse
pouvant être d’amplitude suffisante pour constituer un risque de choc électrique.

Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur qu’il ou qu’elle trouvera d’importantes
instructions concernant l’utilisation et l’entretien de l’appareil dans le paragraphe signalé.

A

AT

TT

TE

EN

NT

TIIO

ON

N::

Risques de choc électrique — NE PAS OUVRIR!

A

AT

TT

TE

EN

NT

TIIO

ON

N::

Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve à

l’intérieur aucune pièce pouvant être reparée par l’utilisateur. Confiez I’entretien et la réparation de
l’appareil à un réparateur Peavey agréé.

A

AV

VE

ER

RT

TIIS

SS

SE

EM

ME

EN

NT

T

: Afin de prévenir les risques de décharge électrique ou de feu, n’exposez pas cet

appareil à la pluie ou à l’humidité. Avant d’utiliser cet appareil, lisez attentivement les avertissements
supplémentaires de ce manuel.

Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen innerhalb des Gehäuses
warnen, die von Ausreichender Stärke sind, um einen elektrischen Schlag verursachen zu können.

Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam
machen, die Handhabung und Wartung des Produkts betreffen.

V

VO

OR

RS

SIIC

CH

HT

T::  

Risiko — Elektrischer Schlag! Nicht öffnen!

V

VO

OR

RS

SIIC

CH

HT

T::  

Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es

befinden sich keine Teile darin, die vom Anwender repariert werden könnten. Reparaturen nur von
qualifiziertem Fachpersonal durchführen lassen.

A

AC

CH

HT

TU

UN

NG

G::

Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerät nicht dem

Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen. 

2

Summary of Contents for Quadra 15P

Page 1: ...Quadra 15P User Manual...

Page 2: ...n Ce symbole est utilis dans ce manuel pour indiquer l utilisateur la pr sence d une tension dangereuse pouvant tre d amplitude suffisante pour constituer un risque de choc lectrique Ce symbole est ut...

Page 3: ...with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 14 Unplug this apparatus during lightning storms or when unused for long pe...

Page 4: ...and mixed mic and line level balanced inputs with Volume control and Loop Thru jacks Bi amplified powered system with 500 Watts total power Both power amps have SPS compression Black Widow BWX 15 prem...

Page 5: ...and should illuminate when the On Off Switch is in the ON position and the AC power cord is connected and plugged into the wall outlet 5 5 P PR RI IM MA AR RY Y I IN NP PU UT TS S O OU UT TP PU UT TS...

Page 6: ...put ON and while setting the microphone level or very loud feedback will occur Damage to the system is likely if this occurs DO NOT connect the inputs of the Quadra 15P to the output of a power amplif...

Page 7: ...the mounting bolt is 3 to 3 1 2 lb feet of torque DO NOT OVERTIGHTEN If an insert spins it has been damaged and the cabinet cannot be flown Never transport the cabinet while mounted on an array bracke...

Page 8: ...anges carefully always turning the Volume control down before plugging and unplugging cables Use of high quality premium cables is recommended with the Quadra 15P as these usually have better shieldin...

Page 9: ...NG G O OF F M MU UL LT TI IP PL LE E Q Qu ua ad dr ra a 1 15 5P Ps s or other Impulse series powered products This unit s multiple parallel inputs allow daisy chaining from one to another Run the firs...

Page 10: ...cking the Mic On switch 7 It should be in the OFF position Make sure that shielded cables have been used to transport the signal to the Quadra 15P s inputs Speaker cables with 1 4 or XLR plugs are mos...

Page 11: ...gh ht t H He ea at t Avoid prolonged exposure to direct sunlight as this may cause the unit to overheat and thermally shut off Excessively hot operating conditions can also cause a thermal shutdown Do...

Page 12: ...our patented SPS compression which virtually eliminates audible power amplifier clipping Multiple molded in handles make transport easy while multiple mounting points top bottom and rear for the Peave...

Page 13: ...l incorporate four tall sturdy rubber feet for floor standing use and four mounting point inserts on the top and bottom each for flying use The outside dimensions shall be 28 5 high by 21 25 wide 11 5...

Page 14: ...male XLR microphone level input that is ON OFF switchable Also has a 1 4 phone jack based loop thru that allows one other Quadra 15P unit to be linked to the first unit for signal source and Volume c...

Page 15: ...e Response 1W 1m On Axis Figure 1 20 50 100 200 500 1k 2k 5k 10k 20k Frequency Hz 1 10 100 Q Directivity Index Q Figure 3 20 10 Di 0 20 50 100 200 500 1k 2k 5k 10k 20k Frequency Hz 30 40 60 80 100 140...

Page 16: ...70 80 90 100 110 dB SPL re 20 Pa Harmonic Distortion at 100 dB 3rd Harmonic 2nd Harmonic 20 50 100 200 500 1k 2k 5k 10k 20k Frequency Hz 50 60 70 80 90 100 110 120 dB SPL re 20 Pa Harmonic Distortion...

Page 17: ...30 o 0 o 30 o 60 o 90 o 1 25 kHz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 1 kHz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 1 6 kHz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 2 5 kHz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 2 kHz 90...

Page 18: ...o 30 o 0 o 30 o 60 o 90 o 8 kHz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 12 5 kHz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 16 kHz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 4 kHz 90 o 60 o 30 o 0 o 30 o 60 o 90 o 6 3 kHz 90...

Page 19: ...60 o 90 o 30 o 60 o 90 o 1 25 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 1 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 1 6 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 2 5 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 2 kHz 0...

Page 20: ...o 60 o 90 o 30 o 60 o 90 o 8 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 12 5 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 16 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 4 kHz 0 o 30 o 60 o 90 o 30 o 60 o 90 o 6 3 kHz 0...

Page 21: ...of date of purchase to your Authorized Peavey Dealer or Authorized Peavey Service Center OR 2 2 Ship the defective item prepaid to Peavey Electronics Corporation International Service Center 412 Highw...

Page 22: ...Peavey Electronics Corporation 711 A Street Meridian MS 39301 601 483 5376 Fax 601 486 1678 http aa peavey com 2002 Printed in U S A 11 02 80304928...

Reviews: