Optima 70 - 2
11
NOTE:
See venting chart for maximum and minimum vertical/horizontal venting configurations.
LOCATING GAS FIREPLACE
This appliance must be installed in any location that is free of plumbing, electrical wiring and
heating or air conditioning ducts. Select a location that is accessible for venting.
See ALLOWABLE TERMINATION LOCATIONS listed in this manual.
VENT TERMINATION LOCATIONS
1.
See ALLOWABLE TERMINATION LOCATIONS and establish a suitable vent termination
location.
2.
In heavy snowfall areas make sure the vent termination is located where it can not be
blocked by snowfall and snow and from snow-removal equipment.
3.
Locate the vent termination away from plants, bushes or any other object near the vent
termination that will interfere or obstruct the air flow around it.
4.
DO NOT recess vent termination into walls, sidings or planters.
5.
Vent terminations located below 7ft (2.13 M) from grade level or anywhere that it can be
a burn hazard to the public, such as patios and balconies, must be protected with an
approved termination cage. If using Archgard Venting System order (Part # C-1).
The fireplace may be installed in any location that maintains proper clearances to combustibles, air
conditioning ducts, electrical wiring and plumbing. Select a location that is accessible for venting See
section Allowable Termination Locations listed in this manual. When the appliance is installed directly
on carpeting, vinyl tile or other combustible materials, other than wood flooring, the appliance must be
installed on metal or wood panel extending the full width and depth of the appliance.