Page 1: ...rtified kit is used Conversion kit required for Propane use WARNING If the information in this manual is not followed exactly fire or explosion may result causing property damage personal injury or lo...

Page 2: ...R OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector ob...

Page 3: ...ency therefore less expensive to operate Adjustable Flame The flame aesthetics and heat output can be adjusted to suit the owner s moods and heating needs Solid Construction It is constructed mainly o...

Page 4: ...0 Approved Vent Components 21 Venting Components Parts List 22 Venting Rear Vent 24 Venting Top Vent 25 Horizontal Venting Instructions 26 Vertical Venting Instructions 27 Operation Instructions Safet...

Page 5: ...and circulating air passageways for the appliance be kept clean Venting terminals shall not be recessed into a wall or siding This gas appliance must not be connected to a chimney flue serving a sepa...

Page 6: ...ance must be installed by a qualified gas appliance installer The installation must conform with the local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 NF...

Page 7: ...Optima ag3600 7 APPLIANCE DIMENSIONS...

Page 8: ...ewall clearance C 6 305 mm from edge of unit Unexposed Back Sidewalls 0 Internal Ceiling 40 1016 mm from floor Floor 0 Mantle See Chart Vertical Vent 1 25 mm to outside surface Horizontal Vent 1 25 mm...

Page 9: ...r in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical code CSA C22 1 Remove or open the bottom louver grill Remove the junction box cover Run the li...

Page 10: ...eplacing the Glass Door Check the condition of the glass and the gasket before installing door Carefully hook the door onto the 4 tabs on the top of the firebox 2 left 2 right Connect the door latches...

Page 11: ...ent connections must be made before installing the logs and embers on the pan burner NOTE Improper placement of logs may cause sooting on the internal parts and glass and will not be covered under war...

Page 12: ...Optima ag3600 12 STEP 1 PLACE REAR LOG 146 ON PINS AND BURNER AS SHOWN LOG PLACEMENT CONTINUED STEP 2 PLACE LEFT LOG 144 ON PIN AND LOG AS SHOWN 144 146...

Page 13: ...Optima ag3600 13 STEP 3 PLACE FRONT LOG 147 ON PINS AND BURNER AS SHOWN STEP 4 PLACE RIGHT LOG 145 ON PIN AND LOGS AS SHOWN LOG PLACEMENT CONTINUED 147 145...

Page 14: ...Optima ag3600 14 STEP 5 PLACE RIGHT LOG 148 AND EMBERS AS SHOWN LOG PLACEMENT CONTINUED 147 146 144 145 148 STEP 6 PLATINUM EMBERS SHOULD BE PLACED ON BURNER AS SHOWN...

Page 15: ...for venting See the ALLOWABLE TERMINATION LOCATIONS page 20 in this manual When the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood flooring the a...

Page 16: ...al shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 5 kPa Failure to do so will damage the appliance s gas valve Such damage is...

Page 17: ...RENCH HERE The pilot flame should have the characteristic as shown in the illustration to the right The flame should not have yellow tips but should engulf the thermocouple and thermopile It can be ad...

Page 18: ...tend warranty to them OPTIONAL WALL SWITCH OR THERMOSTAT Thermostat wall switch wire table Recommended Maximum Lead Length for two wires Wire Size Max Length 14 GA 50 Ft 15 24 M 16 GA 32 Ft 9 75 M 18...

Page 19: ...er 1 2 Remove the top vent heat shield cover 2 3 Remove the outer collar assembly 3 4 Remove the exhaust collar assembly 4 5 Rotate the exhaust collar assembly and the outer collar assembly to the rea...

Page 20: ...veranda porch deck or balcony 12 inches 30 cm E Clearance to unventilated soffit 21 inches from center of termination 53 cm 21 inches from center of termination 53 cm F Clearance to outside corner 0...

Page 21: ...local code restrictions if any regarding the installation of this type of gas appliance Observe the venting charts given in this manual Use vent spacers between the inside 4 101mm and outside 7 178mm...

Page 22: ...B Flashing 7 12 12 12 943S 48 Pipe Length Galvanized 902 Storm Collar 953 11 14 Adjustable Pipe Length Black 911B Vinyl Siding Standoff 950 17 24 Adjustable Pipe Length Black 917B Wall Strap 988 45 El...

Page 23: ...2B DIRECT TEMP 12 ADJ PIPE LENGTH BLACK 1604084 4DT AJ14 DIRECT TEMP TELESCOPE ADJ LENGTH 1604084B 4DT AJ14B DIRECT TEMP TELESCOPE ADJ LEN BLACK 4 x 6 5 8 FITTINGS 1604215 4DT EL45 45 DEGREE ELBOW 160...

Page 24: ...an Archgard SVK 1 TK 1 or 24 snorkel cap part SNK 24 For best venting performance here are some general venting rules 1 Use only vent systems and components certified for use with this appliance 2 Mai...

Page 25: ...2m maximum The total horizontal run up to 20 6 1m maximum Note 4 1 2m minimum of vertical height required Note Maximum vent lengths may be subject to local codes For best venting performance here are...

Page 26: ...H Value Total length of all horizontal sections in feet Note For H V values for 45 venting see Chart IV Elbows are not counted in H or V values Vent chart starts from the top of the unit No restrictor...

Page 27: ...t of the appliance The rear vent configurations do not require a vent restrictor Example 1 V Value 3A 12 1C 3 15 H Value 2B 4 4 V Value Total length of all vertical sections in feet H Value Total leng...

Page 28: ...all a qualified service technician Force or attempted repair may result in a fire or explosion BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because so...

Page 29: ...s established hold knob depressed in the PILOT position for approximately 60 sec 2 Release knob If pilot should go out turn the control knob to OFF position and repeat steps 1 2 and 3 Note this will a...

Page 30: ...ake care not to break them After cleaning the logs must be replaced as per the instructions in this manual Once a year have a qualified service technician Completely inspect the appliance and the vent...

Page 31: ...may be defective Pilot will not remain on after being lit 1 Press the control knob all the way in 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the pilot immed...

Page 32: ...e is yellow and lazy check for lint etc around primary air shutter Increase primary air by opening the primary air shutter if necessary 2 Check for proper placement of the logs and branches Ensure log...

Page 33: ...ghten screw Remove the glass door embers coals and firebox liner panels Remove the 4 screws holding the burner tray and remove it Remove the 2 screws holding the burner and lift it out Use a wrench to...

Page 34: ...icity to the appliance Shut off the gas supply to the appliance and disconnect the gas line to the appliance Remove the glass door logs coals and burner Disconnect the two wires at the front of the va...

Page 35: ...E SIT 820 Nova DATE PURCHASED NAME ADDRESS CITY STATE PROV COUNTRY ZIP POST CODE PHONE NUMBER OWNER COMPANY NAME ADDRESS PHONE NUMBER RETAILER COMPANY NAME ADDRESS PHONE NUMBER INSTALLER MODIFICATIONS...

Page 36: ...0144 LOG LEFT HAND 1 EA 310 0145 LOG RIGHT HAND 1 EA 310 0146 LOG REAR 1 EA 310 0147 LOG FRONT LEFT TWIG 1 EA 310 0148 LOG FRONT RIGHT TWIG 1 EA 311 0077 BRICK PANEL RIGHT HAND 1 EA 311 0078 BRICK PA...

Page 37: ...Optima ag3600 37 C A B BURNER ORIFICE BURNER PAN L K J REPLACEMENT PARTS FAN F G H I E D M...

Page 38: ...ur Authorized Archgard Dealer WHAT TO DO IN THE EVENT OF A PROBLEM Thoroughly read your manual If you cannot solve the problem contact your Archgard Dealer or representative When calling for help plea...

Page 39: ......

Page 40: ...me Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card mm dd yyyy POSTAGE FOLD DOWN AT LINE FOLD DOWN AT LIN...

Page 41: ......

Page 42: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Telephone 604 820 8262 Fax 604 820 8881 Telephone Toll Free 1 877 820 9800 Fax Toll Free 1 866 820 2802 Website www archgard com...