Optima/ag
3600
29
Set the thermostat, if present, to the lowest level. Set the remote switch to the
OFF
position.
Set the flame adjustment knob to the
HI
position. Press slightly and turn the control knob
clockwise
3
to the
OFF
position and wait 5 minutes; thus allowing any gases to escape which
may have accumulated in the combustion chamber.
Note:
LP gases do not vent upward. Then follow step 2 and 3 to establish pilot.
1.
Press slightly and turn control knob counterclockwise
4
to
PILOT
position; depress control
knob and light pilot by repeatedly pressing the sparker. Venting of air may take place at the
pilot prior to the flow of fuel gases. Once flame is established, hold knob depressed in the
PILOT position for approximately 60 sec.
2.
Release knob. If pilot should go out, turn the control knob to
OFF
position and repeat steps 1,
2 and 3.
Note:
this will allow reset of INTERLOCK for proper lighting of pilot.
3.
Once the pilot is established, press and turn control knob counterclockwise
4
to
ON
position.
4.
6.
Turn flame and fan adjustment knob to the desired comfort level using HI / LOW knob.
To turn off the main burner only, set the thermostat to the lowest setting or turn remote switch to
OFF
.
Press and turn the knob clockwise
3
to
PILOT
position.
Press and turn the knob clockwise
3
to the
OFF
position.
5.
Turn thermostat to the desired comfort level or turn the ON/OFF switch to the
ON
position.
OPERATION INSTRUCTIONS
START-UP PROCEDURE
TEMPORARY SHUT-DOWN PROCEDURE
COMPLETE SHUT-DOWN PROCEDURE