31-DVIE33
9
MINIMUM FIREPLACE DIMENSIONS
J
SIDE
VIEW
TOP VIEW
L
M
K
DIMENSIONS
“Controls Out”
DIMENSIONS
“Controls In”
J
20-1/4” (514 mm)
20-1/4” (514 mm)
K
14” (356 mm)
15 1/2” (394 mm)
L
19” (483 mm)
19” (483 mm)
M
30” (762 mm)
33 1/2” (851 mm)
WARNING:
Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
The installer must mechanically attach the marking supplied with the gas fireplace insert to the inside of the firebox of
the fireplace into which the gas fireplace insert is installed.
Cutting of any sheet-metal parts of the fireplace, in which the gas fireplace insert is to be installed, is prohibited.
If the factory-built fireplace has no gas access hole (s) provided, an access hole of 1 1/2” (38.1 mm) or less may be
drilled through the lower sides or bottom of the firebox in a proper workmanship-like manner. This access hole must
be plugged with non-combustible insulation after the gas supply line has been installed.
The fireplace flue damper can be fully blocked open or removed for installation of the gas fireplace insert.
The fireplace and fireplace chimney must be clean and in good working order and constructed of non-combustible
materials. The chimney cleanouts must fit properly.
Refractory, glass doors, screen rails, screen mesh and log grates can be removed from the fireplace before installing
the gas fireplace insert.
Smoke shelves and baffles may be removed if attached by mechanical fasteners. Trim panels must not seal ventila-
tion openings in the fireplace.
Min flue size required 4” (102) x 7” (178)
TOP VIEW
CONTROLS IN
TOP VIEW
CONTROLS OUT
Summary of Contents for 31-DVIE33
Page 28: ...31 DVIE33 28 LIGHTING INSTRUCTIONS ON RATING PLATE...
Page 29: ...31 DVIE33 29 REMOTE CONTROL SETUP AND OPERATION NA on this unit Future option...
Page 30: ...31 DVIE33 30 REMOTE CONTROL SETUP AND OPERATION cont future option N A on this unit...
Page 31: ...31 DVIE33 31 REMOTE CONTROL SETUP AND OPERATION cont...
Page 35: ...31 DVIE33 35 REMOTE CONTROL SETUP AND OPERATION cont...
Page 43: ...31 DVIE33 43...
Page 45: ...31 DVIE33 45 NOTES...
Page 47: ...31 DVIE33 47...
Page 48: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...