WARNING :
If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life. Do not
operate the appliance with the glass front removed, cracked or broken.
Replacement of broken glass should be done by a licensed or qualified
service person.
LIGHTING INSTRUCTIONS - CAUTION
When operated for the first few times, the appliance will emit some odor and fumes. This is due
to the heat from the appliance evaporating the oils and solvents used in fabricating the
appliance. Close off the room to the rest of the house and open all windows. Keep the room
well ventilated, as smoke alarm may sound. Run the appliance for at least 6 hours at maximum
setting with blower set to “OFF” to allow paint to cure (after the installer has checked to ensure
the fan is operational). Smoke and fumes caused by the curing process may cause discomfort
to some individuals.
FIRST FIRE
1.
BEFORE LIGHTING,
smell all around the appliance area for gas. Be sure to smell next
to the floor, because some gasses are heavier than air and will settle on the floor.
2.
IF YOU SMELL GAS,
follow the instructions as listed directly above or as shown on the
front cover of this manual.
3.
Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control system
and any gas control which has been under water.
4.
This appliance is equipped with an ignition device which automatically lights the pilot and
main burner. The pilot and burner light automatically with the hand held remote or with
the switch on the side of the surround if it is activated.
WARNING :
This appliance needs fresh air for safe operation and must be installed
so there are provisions for adequate combustion and ventilation air.
WARNING :
This appliance needs fresh air for safe operation and must be installed
so there are provisions for adequate combustion and ventilation air.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
Summary of Contents for 31-DVIE33
Page 28: ...31 DVIE33 28 LIGHTING INSTRUCTIONS ON RATING PLATE...
Page 29: ...31 DVIE33 29 REMOTE CONTROL SETUP AND OPERATION NA on this unit Future option...
Page 30: ...31 DVIE33 30 REMOTE CONTROL SETUP AND OPERATION cont future option N A on this unit...
Page 31: ...31 DVIE33 31 REMOTE CONTROL SETUP AND OPERATION cont...
Page 35: ...31 DVIE33 35 REMOTE CONTROL SETUP AND OPERATION cont...
Page 43: ...31 DVIE33 43...
Page 45: ...31 DVIE33 45 NOTES...
Page 47: ...31 DVIE33 47...
Page 48: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...