AG2014 70 CM REFRIGERATORS
13.11.2013 / REV NO:
00
37
13.10. Doors cannot be closed
13.11. Sensor
Error
If the Power is “ON” in case of a sensor error, none of the components are driven for 15 min.
Eva sensor error exists
Eva sensor error does not
exist
Air sensor error
exists
crisper comp runs for
20'
and
stops for
40'
crisper runs according to eva’s
specified cut in out
(+5, -20)
value
Air sensor error
does not exist
It performs cut-in at the set
value of the air sensor (“
cut-
out” +2°C
).
OK
13.12. Initial Operation/Power Failure
If the FF Eva sensor temperature is at or above 5°C when the refrigerator is energised, this is called
"initial operation". If this temperature is lower than 5°C, it is called "Power failure".