background image

DT81

5

Additional rear panel functions

 

Data Service switch

: DAB makes provision for providing 

dedicated text and other data services in the multiplex 
datastream.This switch can be set to the ‘in’ position (using the 
end of a ballpoint pen) to prevent data services from appearing 
among the available services on the tuner’s display.

RDI out

: The Radio Data Interface (RDI) is an optical data 

output that may allow future expansion to use certain data 
services via an outboard device such as a personal computer. 
The Data Service switch must be set to the ‘out’ position to 
access the data streams from these services.

Connecting to a power supply

Wrong plug?

Check that the plug supplied with the unit fi ts your supply and 
that your mains supply voltage agrees with the voltage setting 

(115V or 230V) indicated on the rear panel of the unit 

1

.

If your mains supply voltage or mains plug is different, 
consult your Arcam dealer or Arcam Customer Support on 
+44 (0)1223 203203.

Mains lead

The appliance is normally supplied with a moulded mains plug 
already fi tted to the lead. If for any reason the plug needs to 
be removed, it must be disposed of immediately and securely, 
as it is a potential shock hazard when inserted into the mains 
socket. Should you require a new mains lead, contact your 
Arcam dealer.

Plugging in

Push the plug (IEC line socket) of the power cable supplied with 

the unit into the 

POWER INLET

 socket 

2

 in the back of the unit. 

Make sure it is pushed in fi rmly.

Put the plug on the other end of the cable into your power 
supply socket and switch the socket on.

Summary of Contents for DiVA DT81

Page 1: ...DT81 H A N D B O O K Arcam DT81 digital radio tuner ...

Page 2: ...soft damp lint free cloth Do not use paint thinners or other chemical solvents for cleaning We do not advise the use of furniture cleaning sprays or polishes as they can cause indelible white marks if the unit is subsequently wiped with a damp cloth 9 Power sources Only connect the appliance to a power supply of the type described in the operating instructions or as marked on the appliance 10 Powe...

Page 3: ...een designed to very high standards of electromagnetic compatibility If the equipment causes interference to radio television reception which can be determined by switching the equipment off and on the following measures should be taken Reorient the receiving antenna or route the antenna cable of the receiver as far as possible from this appliance and its cabling Relocate the receiver with respect...

Page 4: ...Email ml_mu_support fr bosch de Internet www boschmultimedia de 230 V COAX OPTICAL POWER INLET DIGITAL OUT L R AUDIO OUTPUTS 1 2 REMOTE CONTROL IN OUT FM TUNER INPUT L R DATA SERVICE RDI OUT AERIAL INPUT 4 3 5 7 6 8 1 2 5 Audio output phono sockets two pairs 6 Data Service on off switch and RDI output 7 Digital audio output coaxial and TOSLINK 8 Aerial input BNC locking coaxial Aerial input socket...

Page 5: ...with the unit fits your supply and that your mains supply voltage agrees with the voltage setting 115V or 230V indicated on the rear panel of the unit 1 If your mains supply voltage or mains plug is different consult your Arcam dealer or Arcam Customer Support on 44 0 1223 203203 Mains lead The appliance is normally supplied with a moulded mains plug already fitted to the lead If for any reason th...

Page 6: ...to it Programming a preset First select the service you wish to assign to a preset Now press STORE 1 8 or STORE 9 16 and then briefly press the appropriate preset button to store the service It is not possible to assign secondary services to presets only primary ones since secondary services are often broadcast on a temporary basis and they may change from day to day Selecting a preset To select p...

Page 7: ...crolling text used by most broadcasters to display programme information such as song titles useful phone numbers and website addresses Signal quality meter The signal quality meter is a simple bargraph which gives a quick visual guide to reception quality Technically it is an inverse measure of the Viterbi error rate with zero errors at full scale all segments are lit and 300 errors second with a...

Page 8: ...ace anything in front of the tuner where the IR receiver is located or the remote control may not work TUNE buttons These buttons enable you to scroll through the available services Depending on how the tuner is set up the service is either selected automatically after 2 5 seconds or when you press the BAND button For more information on this feature see Selection mode on page 7 BAND This button h...

Page 9: ...operation 3 Display shows No services stored at the end of the search This will happen when the signal strength is insufficient due to either a poor aerial or lack of an available DAB signal 4 Audio is lost and display shows signal weak muted This happens when the signal becomes weak A better aerial is required 5 Audio is lost and display shows Service ended or Arcam DAB Tuner This occurs if the s...

Page 10: ...Audio data rate maximum 256kbits s MPEG layer II protection level 3 Number of stored services maximum 128 Aerial Impedance 50Ω nominal in operational frequency range Connector BNC General Supply voltage 115V or 230V AC Power consumption 30VA operational 5VA standby Size W x D x H 435 x 320 x 83mm Weight net 4 6kg Weight packed 6 1kg Supplied accessories Mains lead CR 389 remote control handset and...

Page 11: ... be packed in the original packing and returned to the dealer from whom it was purchased or failing this directly to the Arcam distributor in the country of residence It should be sent carriage prepaid by a reputable carrier NOT by post No responsibility can be accepted for the unit whilst in transit to the dealer or distributor and customers are therefore advised to insure the unit against loss o...

Page 12: ...PEMBROKE AVENUE WATERBEACH CAMBRIDGE CB5 9PB ENGLAND telephone 44 0 1223 203203 fax 44 0 1223 863384 email support arcam co uk website www arcam co uk SH102E Issue 1 ...