Flex Mini Instruction Manual
November 2015
Page 11 of 17
2.2.2 Jumper Settings
JP1 Open
→
Remote pairing function (press Pairing button required).
JP1 Short
→
Remote pairing function (press Pairing button not required).
JP2 Open
→
System normal.
JP2 Short
→
Display receiver software version.
JP3 Open
→
Normal toggled function set on the dip-switches.
JP3 Short
→
All toggled functions set on the dip-switches deactivates
when shutting off the transmitter power (keypad type 2)
and when the Stop button is pressed (keypad type 3).
JP4 ~ JP8
→
Reserved for future functions.
2.2.3 External Programming
Other settings not listed in this manual can be programmed via the external programmer
unit. Please contact ARC representative in your area for more details.
Transmitter
Receiver
Other available functions set via external programmer unit:
1) On & Off function not affected by the transmitter power On/Off and Stop command.
2) Magnet On/Off function.
3) On + Start / Off + Start function (keypad type 3 only).
2.2.4 Fuse Ratings
Fuse #
110~120VAC
220~240VAC
380~400VAC
410~460VAC
24VAC
42 & 48VAC
9~36VDC
F2 & F3
5.0A
5.0A
5.0A
5.0A
5.0A
5.0A
5.0A
F1
0.5A
0.5A
0.5A
0.5A
1.0A
1.0A