Flex ECO 6S/X MRX Instruction Manual
August 2017 v1.0
Page 15 of 34
ON DIP
S2 DIP 10
4.1.3 Remote Pairing
A. Transmitter-to-Transmitter Pairing:
1) Press down the STOP button (transmitter power off).
2) Press and hold PB1 and PB3 at the same time.
3) Reset the STOP button by rotating it clockwise or counter
clockwise, it will pop up (transmitter power on).
4) Let go PB1 and PB3 at the same time (entered Remote
Pairing mode). The Status LED displays firmware version
with red, green and orange blinks.
5) Output data (original transmitter) by press and hold PB2
(Status LED off and LED-B constant red).
6) Receive data (new transmitter) by press and hold PB1 (Status LED blinks green
and LED-A constant red).
7) When the Status LED (receiving data end) turns to constant green while both
pushbuttons are still pressed down the pairing is completed.
8) Exit Remote Pairing mode by pressing down the STOP button (transmitter power off).
→
Output data – original transmitter
Receive data – new transmitter
(press and hold PB2)
(press and hold PB1)
Note:
During remote pairing make sure the distance between the two transmitters is within 1 meter.
B. Receiver-to-Transmitter Pairing:
S2 dipswitch position 10 set to “0” (down):
After the transmitter enters the Remote Pairing
mode, output receiver data by press and hold the PAIRING button located on the receiver cover
and receive data by press and hold PB3 on the transmitter, both at the same time. When the
transmitter Status LED turns to constant green while both pushbuttons are still pressed down
the pairing is completed.
→
→
S2 dipswitch position 10 set to “0” Output data – receiver
Receiving data – transmitter
(press and hold the Pairing button) (press and hold PB3)
S2 dipswitch position 10 set to “1” (up):
After the transmitter enters the Remote Pairing mode,
press and hold PB3 on the transmitter until the Status LED turns to constant green the pairing is
completed.
Make sure the pairing process is executed within distance of 10 meters from one
another and no other active receivers nearby. During pairing process the receiver MAIN relays