3.2
Changing the grinding belt
When the grinding belt is worn out it must be replaced which is done as follows: The
lid plate (A) (see
fig.: 3.2
) on the box cover is opened and the handle (B) is pulled
downwards. This way the tension is released from the grinding belt (C) to be able to
dismount it and replace it with a new one to be mounted in reverse order. Check to
see if the direction of the arrows on the back of the grinding belt aligns with the
rotational direction. When the new grinding belt is mounted it is necessary to check
for alignment by the handle (D), which is loosened so the telescope arm (E) and top
roll (F) can be turned along until the grinding belt runs straight on the contact wheel.
Now tighten the handle (D).
Only perform this adjustment of the grinding belt by pulling the grinding blet by
your hands and NOT with the machine turned ON.
Fig.: 3.2