8.1 Menu System
57
8.1.4
The Setup Menus
No.
Setup Menus
Setup Items
1
Set Serial COM 1?
Main RS-232 port parameters and broadcast
2
Set Serial COM 2?
Second RS-232 port parameters and broadcast
3
Set Local Time?
Set local offset, daylight saving mode
4
Set Out-Of-Lock?
Set out-of-lock mode, and time interval before alarm occurs
5
Set Relay Config.?
Set out of lock, alarm, fault and stabilized indicators
6
Set Back Light?
Set to ON, OFF or AUTO mode
7
Set System Delays?
Set combined antenna group delay and cable delay in nanoseconds
8
Set Prog. Pulse?
Set mode, pulse width and time zone
9
Set IRIG Time Data?
Set IRIG-B time zone and IEEE C37.118.1 control bits
10
Set Event/Deviation?
Set for event, or 1 PPS deviation
11
Set Option Control?
Set up auxiliary board option
12
Set C Disp. Format?
Configure the month and day format of the large display of Model 1201C
Table 8.2: Front-Panel Setup Menu Definitions
8.1.5
Default Firmware Settings
When shipped from the factory, and unless specified otherwise, all models will be configured with
default settings.
Most users elect to modify the clock settings to fit their locale and desired
operation. Default settings are listed in Table 8.3.
Menu Item
Default
Menu Item
Default
COM 1 Port
9600, 8, N, 1
COM 2 Port
9600, 8, N, 1
Local Time & DST
none, OFF
Out-of-Lock
01 minute
Relay Config.
ON, ON, ON, OFF
Backlight
Auto
System Delays
60 ns
Prog. Pulse
IRIG-B
IRIG Time Data
UTC, C37.118.1 OFF
Event/Deviation
1 PPS Deviation
Option Control
None
C. Display Format
MM/DD//YY
Table 8.3: Default Clock Settings
a
Default settings for the four triggering conditions: Out of Lock, Fault, Alarm, Stabilized
8.1.6
Configuration Flow Diagrams
This section explains how to use the setup menu flow diagrams in the following sections. The LCD
screens display contents of each menu. Use the lower row of keys to configure clock settings.
1. Always start configuring by pressing SETUP.
2. Scroll through the menus using either UP or DOWN.
3. When you see the specific menu to configure, press ENTER to start configuring.
4. Once in the individual menu, use UP or DOWN to make selections.
5. To configure numerical values, see Section 8.1.7 below.
6. Press ENTER to install the new value and move to the next menu.
7. Press any of the upper row of keys to exit the configure menus.