3 Service & Maintenance
14
3.2 Fuse And Wiring Loom
Replacement
The CKMTP12 supply wiring loom is connected to the compressor by a sealed
high current rated connector. Should the loom or battery clamps be damaged
and need replacement the supply loom can simply be unplugged and
replaced.
The supply wiring loom contains two inline fuses near the
battery end of the positive (+, RED) wire providing
independent circuit protection for each motor. If either of the
fuses requires replacing, they can be removed by opening the
black rubber fuse housing cover and pulling straight outward
on the fuse until it slides free of the fuse block. The fuse
should only be replaced with a fuse of the same type (maxi
blade type) and of the same amp rating (40A) or less.
3.3 Draining Moisture From The Air Tank
After prolonged compressor use moisture can accumulate in the air tank and
as a result the air tank should be drained after approximately 10-20 hours of
compressor run time. The air tank can be drained as follows:
•
With the compressor connected and switched on as described in Section
2.2, connect the air blow gun to the air hose.
•
Lift the compressor carry case off the ground by the handle, leaving the lid
open.
•
Operate the blow gun with the nozzle pointing towards the ground and
away from people. Press the blow gun trigger and the accumulated
moisture in the air tank will be expelled through the blow gun.