Water connection
6.2.1
Safety guidelines
- The pump must always be installed below the liquid level.
- The suction line must be as short and direct as possible.
- Avoid elbows and the enlargement of the diameter in the pipeline to avoid air stagnation.
- The size of the suction and delivery lines must be AT LEAST equal to the nominal diameter of the size of the relevant opening.
- The suction line must be free from air leaks.
- Avoid, if possible, elbows and narrowing in the pipeline on the delivery line, this is to limit possible loss of pressure.
OUT
IN
Inlet/outlet coupling
Fork
Thread
(BSP /NPT)
Clamp
T7F
T6F
2"
1 1/2"
2" Full Port
2" Std. Port
Pipelines minimum diameter
50 mm / 2"
38 mm / 1 1/2"
suction (IN)
delivery (OUT)
Couplings diameter and recommended pipelines
6.2.2
Water/air bleed
- Install a breather pipe (Item 2 Fig. 2) in one of the delivery retaining plugs placed on the pump.
The tube diameter must be 6 mm or 1/4".
- Choose the plug located in the highest point according to the installation position of the pump (Fig.
9
) in order to eliminate any
air trapped in the pump and to allow a minimum motion of the liquid also when the control unit connected to the pump is not
spraying.
Fig.
8
Tab. 6
Fig.
9