42
SELETRON CONNECTION
13
SELETRON CONNECTION
PLEASE CAREFULLY FOLLOW THE INSTRUCTIONS PROVIDED IN THIS CHAPTER. ANY MISTAKES
DURING SELETRON PAIRING/REPLACEMENT MAY LEAD TO SYSTEM OPERATION FAILURE.
Seletron does not respond.
Power supply error on Seletron devices: power voltage lower than the allowed value.
Correct operation.
Fig. 85
BEFORE PROCEEDING, MAKE SURE YOU ARE ABLE TO HEAR THE
ACOUSTIC SIGNALS COMING FROM THE MONITOR LOCATED IN THE
CABIN (DOORS OPEN, ETC.).
• Access the menu (
par.
)
Data and settings > System status > Seletron status
• Make sure that ALL SELETRON DEVICES ARE DISCONNECTED: they must
be shown on the display only with the symbols
, as shown in
Seletron 1
Seletron 2, 3, ecc.
Fig. 86
BEFORE CONNECTING A NEW SELETRON, MAKE SURE THAT THE PREVIOUS ONE HAS BEEN
PAIRED
, THAT THE ACOUSTIC SIGNAL HAS BEEN MADE AND THAT THE RELEVANT GREEN SYMBOL HAS
BEEN DISPLAYED. IN CASE OF ERRORS DURING THE PAIRING PROCEDURE, (THE DISPLAY SHOWS THE
SYMBOL
) RESET ALL IDENTIFICATION NUMBERS AND REPEAT THE PROCEDURE FROM THE START
(
ID Reset
,
PAR.
)
.
• Connect the first Seletron.
Seletron no. 1 is the first on the left, when looking at the boom from behind (
WAIT FOR THE ACOUSTIC SIGNAL BY THE MONITOR.
WAIT FOR THE MONITOR TO DISPLAY THE GREEN SYMBOL FOR THE CONNECTED SELETRON (
).
•
ONLY NOW
IS IT POSSIBLE TO PROCEED WITH THE INSTALLATION OF THE FOLLOWING SELETRON.
WARNING: ALL SELETRON DEVICES MUST BE INSTALLED IN A SEQUENCE FROM LEFT TO RIGHT
(when looking at the boom from behind).
• Repeat the above steps, connecting all remaining Seletron devices from left to right until the end of the boom.
• Connection sequence if end nozzles are present (
par.
NOZZLES FOR “Buffer zone”
Start by connecting Seletron for "Buffer zone" located at the left end of the
boom, then connect all the "normal" Seletrons from left to right, and lastly
connect Seletron for "Buffer zone" located on the right end of the boom.
“Fence” NOZZLES
Start by connecting all the "normal" Seletrons from left to right, then
connect the "Fence" Seletron located on the left end of the boom
and lastly connect the "Fence" Seletron located on the right end of
the boom.
RIGHT
"Buffer zone"
LEFT
"Buffer zone"
“Fence” Nozzles
CONTINUES > > >
~4
seconds