background image

3

CONTENTS

1  Product description ........................................................................................................................................................... 4

1.1  Intended use............................................................................................................................................................... 4

2  Flowmeter assembly ......................................................................................................................................................... 4

2.1  Monitor rotation .......................................................................................................................................................... 5
2.2  Dimensions (mm) ....................................................................................................................................................... 6
2.3  Hydraulic connections ................................................................................................................................................ 6

2.3.1 Hydraulic connection for brass/fork connections ....................................................................................................... 6

2.4  Power supply .............................................................................................................................................................. 7

2.4.1 Battery replacement ................................................................................................................................................... 7

3  Controls in the menu ......................................................................................................................................................... 8
  Menu structure ................................................................................................................................................................... 9
4  Preliminary setup for use................................................................................................................................................ 10

4.1 Calibration ................................................................................................................................................................ 10

4.1.1  Automatic calibration ................................................................................................................................................10
4.1.2  Manual calibration .....................................................................................................................................................11

4.2  Flowrate alarms ........................................................................................................................................................ 12
4.3 Display ...................................................................................................................................................................... 12
4.4  Energy saving ........................................................................................................................................................... 13
4.5 Options ..................................................................................................................................................................... 13

4.5.1 Language ................................................................................................................................................................. 13
4.5.2 Units of measurement .............................................................................................................................................. 14
4.5.2.1 Rate units of measurement ................................................................................................................................... 14
4.5.2.2 Volume units of measurement ............................................................................................................................... 14

4.6 Test ........................................................................................................................................................................... 15

4.6.1 Display test ............................................................................................................................................................... 15
4.6.2 Keys test ................................................................................................................................................................... 15

5  Use    .............................................................................................................................................................................. 16

5.1  Partial totalizer reset ................................................................................................................................................. 16

6  Cleaning and repair ......................................................................................................................................................... 17

6.1 Troubleshooting ........................................................................................................................................................ 17
6.2  Paddle cleaning and replacement ............................................................................................................................ 18
6.3  OR replacement ....................................................................................................................................................... 19

7  Technical data  ................................................................................................................................................................. 20
8  Disposal at the end of service  ....................................................................................................................................... 20
9  Guarantee terms .............................................................................................................................................................. 22

Summary of Contents for DigiWOLF 4627 Series

Page 1: ...4628405 4628506 4628707 CELL POWERED VERSION Software rel 1 0X INSTALLATION USE AND MAINTENANCE digi...

Page 2: ...ment to which it refers and must accompany the equipment in case of sale or change of ownership Keep it for future reference ARAG reserves the right to modify the specifications and instructions regar...

Page 3: ...10 4 1 1 Automatic calibration 10 4 1 2 Manual calibration 11 4 2 Flowrate alarms 12 4 3 Display 12 4 4 Energy saving 13 4 5 Options 13 4 5 1 Language 13 4 5 2 Units of measurement 14 4 5 2 1 Rate un...

Page 4: ...man consumption 2 Flowmeter ASSEMBLY Install the flowmeter at least 20 cm from the elements that could cause turbulence inside the tubes valves bends constrictions etc The flowmeter can be installed i...

Page 5: ...e seen these correspond to the two possible monitor positions parallel and perpendicular to the body DigiWolf is supplied with the sensor in position A parallel to the body With the aid of a screwdriv...

Page 6: ...ementation on already operating systems it is necessary to follow all safety rules described herein System assembly and start up must be carried out by expert personnel according to the safety rules s...

Page 7: ...ery case and that the lid seal remains in its seat A B C To avoid damaging the device replace low batteries as soon as this symbol is displayed Remember to remove the batteries when the device is not...

Page 8: ...for 2 seconds at the same time to access setup menu Setup menu Calibration Flowrate alarms Display A B SELECTION AND ACCESS TO MENU ITEMS A Press in succession to move through items the selected item...

Page 9: ...sion Sensor frequency 2 98V Par 4 6 1 Test Display test Sensor frequency Battery voltage Par 4 6 2 Test Keys test Battery voltage Display test Setup menu Calibration Flowrate alarms Display Setup menu...

Page 10: ...display will start to show the incre asing value of the measured quantity of liquid Once liquid passage has finished the value on the display will not change any more At this point press OK In the low...

Page 11: ...on Flowrate constant Min value Max value C 1 50000 B D A 0600 0 2 Using the suitable keys set the value of the flowmeter constant A Press to toggle from one digit to another B Press in succession to m...

Page 12: ...D A 0040 0 0 l min o 3 Set flowrate alarm value A Press to toggle from one digit to another B Press in succession to modify the value of the digit highlighted by the cursor C Press to save changes or...

Page 13: ...saving Under the selected item the currently set value will be displayed Press OK to access modification of the selected item Backlight shut off Min value Max value C 1 300 B A 30 0 s C 2 Set the valu...

Page 14: ...te units of measurement selection 2 1 2 Flowrate l min GPM m h 3 1 Select measurement unit using 2 Press OK to save or ESC to exit without saving 4 5 2 2 Volume units of measurement Units of measurem...

Page 15: ...ration of the display on the device Test Display test Sensor frequency Battery voltage Access display test menu Setup menu Test Display test Press OK The display shows all pixels on Press ESC to retur...

Page 16: ...will zero Do not place DigiWolf under pressurized water Use the flowmeter only within recommended rate range Tab 2 Par 2 3 1 Beyond these limits the flow meter may give out incorrect data To avoid dam...

Page 17: ...g the sensor or the paddle check for the correct reading of the flowmeter Proceed to a new calibration if necessary 6 1 Troubleshooting FAULT CAUSE REMEDY The display is off No power supply Check for...

Page 18: ...several hours 6 Wash the paddle group thoroughly with running water and check its correct operation If necessary replace the complete paddle group with its suitable spare part code 4626000 500 7 Refit...

Page 19: ...as follows 1 Remove the fork from the ring nut using a screwdriver 2 Remove the ring nut OR replacement Replace the ORs code G10051V ARAG spare parts catalogue 3 Refit the sensor housing block ensurin...

Page 20: ...Portugu s Fran ais Deutsch Cesky Polski Magyar Rate units of measurement l min Units of measurement settings l min GPM m3 h Volume units of measurement litres Units of measurement settings l gal m3 7...

Page 21: ...Notes 21...

Page 22: ...allation and regulation damage or malfunction caused by the lack of ordinary maintenance such as cleaning of filters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing...

Page 23: ...i nella seguente Direttiva Europea 2004 108 CE e successive modificazioni Compatibilit Elettromagnetica Riferimenti alle Norme Applicate EN ISO 14982 Macchine agricole e forestali Compatibilit elettro...

Page 24: ...ALY Via Palladio 5 A Tel 39 0522 622011 Fax 39 0522 628944 http www aragnet com info aragnet com Only use original ARAG accessories and spare parts to maintain safety conditions foreseen by the constr...

Reviews: