23
Par.10.2
Shifting
of the cursor
Quits the menu or
the data change
Confirms access to menu
or data change
Menu item scrolling or
Data increase/decrease
11.16
Tank source
Tank source
Manual
Fig. 51
In this menu select a tank level reading mode.
The management of the
Tank source
, described in par. 11.17, will be different according to the selected mode.
Possible options:
>
Manual
Level Sensor
The level sensor installed in the system allows displaying the tank level in real time.
This mode operates correctly ONLY if the level sensor has been calibrated, or if the calibration of a
similar tank has been loaded from pendrive.
The procedure is described below, under section
Tank profile
>
Load
.
11.17
Tank setup
Tank Setup
. . .
Fig. 52
Allows to set data relevant to the tank.
After selecting the menu
Tank Setup
, press
OK
to gain access to the sub-menus.
>
Tank volume
(can be modified only in mode
Tank source
>
Manual
)
This parameter sets the quantity of fluid the tank can contain: it indicates the maximum quantity of fluid that can be filled in the tank by the user.
If there is a level sensor, the computer displays the tank capacity calculated after the calibration.
>
Tank reserve
This parameter sets the "reserve" value below which the computer triggers a visual and acoustic alarm: when the reserve value is reached during the spraying, the
tank symbol (Fig. 53) blinks on the display.
32.1 GPA
7.58 MPH
M
Fig. 53
The acoustic alarm stops when the tank is completely empty.
>
Calibration
*
: enters the calibration procedure of the level sensor.
Tank source
>
Level Sensor
par. 11.16
* MENU VISIBLE ONLY WITH SPECIFIC SETTINGS:
TO VIEW IT, ENABLE THE INDICATED OPTION.
The level sensor calibration is ONLY possible if the system is provided with a flowmeter (par. 11.10 and 11.11)
).
Before starting the procedure carry out the following operations:
1
Make sure that the main switch is in the
OFF
position.
2
Fill in the tank with clean water WITHOUT ADDING CHEMICAL SUBSTANCES.
The tank must be full.
Visually check the reached level.
------ Menu ------
--- Advanced ---
+
5
1
OFF
32.1 GPA
0.0 MPH
M
3
4
3
From the job screen check that the manual mode is active
(the display shows
M
).
Otherwise activate it by pressing
AUTO
.
4
Set the output to the maximum value by keeping the control valve switch pressed
(nearly 7 s).
5
Switch off the computer and on again in advanced setup mode.
6
Enter the
Tank source
menu, activate the
Level Sensor
mode.
7
Enter the
Tank Setup
menu and select
Calibration
.
8
Bravo 180S requests to enter the tank capacity: enter the value.
Tank source
Level Sensor
6
Rated volume
528 gal
8
Tank Setup...
Calibration...
7
ADVANCED SETUP