21
Par.10.2
Shifting
of the cursor
Quits the menu or
the data change
Confirms access to menu
or data change
Menu item scrolling or
Data increase/decrease
ADVANCED SETUP
Go ahead!
0 pulses
300 feet
Fig. 41
- After selecting
Automatic calc.
(point
3
), the display indicates that it is possible to move forward with the
vehicle.
- Cover the requested distance: the number of pulses will increase during the path. Stop the tractor at the end of the
distance.
- Press
OK
to stop the counting. The computer will indicate the calculated constant.
Wheel constant has been saved.
Take measurements with tyres at the operating pressure.
This test must be performed on medium-hard terrain; for application to very soft or very hard terrain,
rolling diameter may vary, leading to inaccurate output calculation; when this is the case, repeat the
procedure.
During the test cover the distance with the tank filled up to half capacity with water.
Error!
Alarm displayed during the automatic calculation: repeat the procedure, calculation not valid; the error can occur
even if the wheel has been replaced in a wrong way or if the sensor is too far from the detection points.
In this case check the sensor installation and repeat the procedure.
If the problem persists, contact the installer.
Wheel 1/3
20.09 in./pls
Fig. 42
>
GPS source
>
No
Yes
With option
Yes
, the computer is preset to receive speed data from the GPS receiver directly connected to the
auxiliary port.
GPS source
No
Fig. 43
11.9
Valves
Valves
. . .
Fig. 44
Set the type of valves installed on the system and the relevant data.
After selecting the menu
Valves
, press
OK
to gain access to the sub-menus.
>
Section valves
: indicate the type of installed section valves.
2-Ways
: valves without calibrated backflows
3-Ways
: valves with calibrated backflows
>
Sections manag.
Indicate the section valve operation mode, especially if the section
automatic closing is active when the main control valve is closed.
Manual (P Mode)
Auto (M Mode)
• "P" operation mode (option
Manual
):
The section valves are controlled independently.
Main switch control functions do not affect section valve opening or closing.
• "M" operation mode (option
Auto
):
The section valves are closed or opened acting on the main switch provided the section valve
specific switch is in the correct position, i.e. if the section switches are set to OFF (lever down),
acting on the main switch the sections will not be controlled.
If one or more section valve switches are set to ON (lever up), opening or closing the main switch
opens or closes the section valves as well.
>
Regulation
: indicate the type of installed control valve.
2-Ways
3-Ways
>
Main
: indicate the type of installed main control valve.
2-Ways
: drain valve (valve TYPE - Arag 463 series)
3-Ways
: main valve (valve TYPE - Arag 464 - 471 series)
11.10
Flowmeter
Flowmeter
Orion
Fig. 45
Select the type of flowmeter installed:
Orion
Other....
Summary of Contents for Bravo 180S Series