8
4.4.2
Alfa-Bus interface positioning
Position the Alfa-Bus interface in a sheltered place, next to the sensors it is to be connected to, and
make sure that all cables can reach the device.
CAUTION: route wiring in a bend, as shown in Fig. 6a.
- Fasten Alfa-Bus interface using the supplied screw.
- Connect wiring (
S
) to position / RPM sensor.
- Connect wiring (
B
) to a connector of the Alfa-Bus line.
- Connect wiring (
A
) to the wiring for expansion of the Alfa-Bus line (if any).
If left unused, plug connector off with a cover (
code ECS0040
- not supplied).
- Fasten interface using the supplied tie, to avoid damages.
- Fasten the wiring using ties to avoid damages.
4.4.3
Sensors cable positioning
Lay down the wiring so as every branch is positioned at the seed row.
Fig. 6a
Fig. 6b
Fig. 6c