1 Warnings 

 

It is a LEGAL REQUIREMENT that the installation of all new or replacement, wood or solid fuel 

heating appliances, obtain Building Control approval from your local Authority or the installation 

work must be carried out through a government approved Competent Persons Scheme.  

A list of all Competent Person Schemes can be found at:

 

www.gov.uk/guidance/competent-person-scheme-current-schemes-and-how-schemes-are-

authorised 

 

 

Any manufacturer’s instructions must not be taken as overriding statutory requirements. 

 

Please Note: Classification of these appliances is for intermittent use only.  

 

Do not use aerosol sprays or any other flammable materials near the appliance when in use. 

 

Do not use the appliance as an incinerator. 

 

Use only recommended fuels. STRICTLY NO unsuitable and non recommended fuels or materials 

or liquid fuels allowed. Pure petroleum coke or Bituminous house coal must NOT be burned in this 

appliance. The use of these fuels will invalidate the appliance guarantee. 

 

Please ensure that air inlet vent grills to the dwelling are not obstructed or liable to be blocked. 

 

Caution must be exercised during operation of the appliance as both internal and external surfaces 

will be hot to touch.  Use the stove mitten provided when the appliance is in operation. 

 

A fireguard conforming to BS 8423:2002 should be used in the presence of children or  elderly 

people.  

 

Always observe the distances to combustible materials as stated on the appliance Data Plate and 

in the Technical Data section of this manual. Ensure no soft furnishings or combustible materials 

are susceptible to heat radiating from the appliance. 

 

Under NO circumstances should the stove be operated for extended periods with the main fire door 

open. This will result in an over firing situation and will lead to severe damage to the stove and flue 

system. Ignoring the warnings could lead to damage/injury to persons and/or property. 

 

Arada Ltd will not be responsible for any consequential or incidental loss or injury however caused. 

 

IMPORTANT INFORMATION

 

Summary of Contents for Ecoboiler

Page 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK 560 SPECIFIC Rev 10 ISSUE DATE 01 4 2016 BS EN 13240 2001 A2 2004 BS EN 13229 2001 A1 2003 A 2004 CE Ecoboiler Stove User Guide...

Page 2: ...ime of heating satisfaction Should you have any questions about your stove which are not covered by this manual please contact the Arada retailer in your area call our technical support department on...

Page 3: ...1 Refuelling on to a low fire bed 11 6 Further information for all stove owners 6 1 Reduced burning 11 6 2 Over firing 12 6 3 Chimney fires 12 6 4 Periods of non use 12 6 5 Ash removal 13 6 6 Multi f...

Page 4: ...NOT be burned in this appliance The use of these fuels will invalidate the appliance guarantee Please ensure that air inlet vent grills to the dwelling are not obstructed or liable to be blocked Caut...

Page 5: ...ained in order to determine the moisture content of your wood fuel Wet wood must not be used as this will greatly contribute to the creation of tar and creosote which may in extreme cases run down the...

Page 6: ...nce Suitable provision for combustion and ventilation air depending upon Building Regulations have been undertaken by the installation fitter Consideration must be given for the need for extra ventila...

Page 7: ...y Air The primary air is supplied through the thermostatically controlled air inlet beneath an access cover on left side of your stove This should have been calibrated when the stove was installed See...

Page 8: ...assist whilst lighting the fre Once lit the Easy Boost inlet should be used for a temporary increase in boiler output when required It should be used for short periods only and will temporarily overri...

Page 9: ...criss cross grid pattern on top of the grate The use of two or three fire lighters may assist in lighting the kindling 2 Fully open the airwash and Easy Boost air control and light the fire lighters...

Page 10: ...od fuel see steps 1 2 and 3 of section Burning Wood with kindling and fire lighters 3 Once flue draw has been established carefully load the stove with fuel and close the door 4 When the fire is well...

Page 11: ...a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable period If...

Page 12: ...ce to reduce the air supply to the stove Move items of furniture and combustibles away from the surrounding area of the stove to reduce the risk of fire and allow access for the fire service Ensure ac...

Page 13: ...al container Even if ash appears cold red hot embers may be concealed and could easily start a fire or cause injury 6 6 Multi fuel grate except Ecoboiler Wood The grate in your Ecoboiler stove compris...

Page 14: ...It is then these objects such as the chimney breast hearth etc which heat the surrounding air in the room 7 2 Hot Water Your stove also has a boiler jacket integrated into the rear of the stove This...

Page 15: ...w sits square to the body if not repeat the previous step If the fire door needs to be raised please follow the instructions below 1 When the appliance is cold open the fire door so that it is at righ...

Page 16: ...your Arada stove We appreciate that we have given you a lot of information to read but we hope it has been clear and helpful and that you are now able to enjoy the full benefits of your stove However...

Page 17: ...a red oxide colouring will demonstrate the over heating of internal parts body paint which has turned dusty white is also indicative of such use The following guarantee periods shall apply in respect...

Page 18: ...ere flue draw readings have not been made to confirm a suitability of the flue The manufacturer s decision as to whether this condition has been satisfied shall be final 7 The guarantee does not cover...

Page 19: ...ifications have been made to the stove which have been carried out by anyone other than Arada or its authorised representatives or approved dealers 14 All guarantee periods commence on the date of pur...

Page 20: ...Date of issue 19 7 2016 BK560 Rev 10 All Arada Stoves are manufactured in the UK Arada Ltd The Fireworks Weycroft Avenue Axminster Devon EX13 5HU United Kingdom www aradastoves com T 44 0 1297 632050...