Arada Ecoboiler User Manual Download Page 19

 

  BK560 Rev 10 

Page 19 

   

Ecoboiler Stove User Guide 

11.  The guarantee is only valid if the stove is serviced and checked annually by a suitably 

qualified heating engineer, with documentation to be retained and produced in the event of a 

claim being made. 

12.  The guarantee is only valid where any spare parts used are supplied by Arada or an 

approved Arada dealer. The use of spares other than those supplied by Arada Limited shall 

invalidate the guarantee. Parts can be purchased through an approved dealer or directly 

from Arada online at www.aradastoveandspares.com. 

13.  The guarantee is not valid where any repairs or modifications have been made to the stove 

which have been carried out by anyone other than Arada or its authorised representatives or 

approved dealers. 

14.  All guarantee periods commence on the date of purchase and are non-transferable and 

solely for the benefit of the original purchaser of the stove. 

 

10.3 General 

 

Our guarantee is offered as an addition to your statutory rights and will not effect your  statutory 

rights. You can obtain information about your legal rights from Trading Standards offices or a 

Citizens Advice Bureau. 

 

If you believe your appliance is not working correctly or it has broken components, in the first 

instance please contact your local retailer or installer for assistance. 

 

This guarantee is applicable in the UK only and operates exclusively in accordance with the laws 

of England and Wales. 

Summary of Contents for Ecoboiler

Page 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK 560 SPECIFIC Rev 10 ISSUE DATE 01 4 2016 BS EN 13240 2001 A2 2004 BS EN 13229 2001 A1 2003 A 2004 CE Ecoboiler Stove User Guide...

Page 2: ...ime of heating satisfaction Should you have any questions about your stove which are not covered by this manual please contact the Arada retailer in your area call our technical support department on...

Page 3: ...1 Refuelling on to a low fire bed 11 6 Further information for all stove owners 6 1 Reduced burning 11 6 2 Over firing 12 6 3 Chimney fires 12 6 4 Periods of non use 12 6 5 Ash removal 13 6 6 Multi f...

Page 4: ...NOT be burned in this appliance The use of these fuels will invalidate the appliance guarantee Please ensure that air inlet vent grills to the dwelling are not obstructed or liable to be blocked Caut...

Page 5: ...ained in order to determine the moisture content of your wood fuel Wet wood must not be used as this will greatly contribute to the creation of tar and creosote which may in extreme cases run down the...

Page 6: ...nce Suitable provision for combustion and ventilation air depending upon Building Regulations have been undertaken by the installation fitter Consideration must be given for the need for extra ventila...

Page 7: ...y Air The primary air is supplied through the thermostatically controlled air inlet beneath an access cover on left side of your stove This should have been calibrated when the stove was installed See...

Page 8: ...assist whilst lighting the fre Once lit the Easy Boost inlet should be used for a temporary increase in boiler output when required It should be used for short periods only and will temporarily overri...

Page 9: ...criss cross grid pattern on top of the grate The use of two or three fire lighters may assist in lighting the kindling 2 Fully open the airwash and Easy Boost air control and light the fire lighters...

Page 10: ...od fuel see steps 1 2 and 3 of section Burning Wood with kindling and fire lighters 3 Once flue draw has been established carefully load the stove with fuel and close the door 4 When the fire is well...

Page 11: ...a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable period If...

Page 12: ...ce to reduce the air supply to the stove Move items of furniture and combustibles away from the surrounding area of the stove to reduce the risk of fire and allow access for the fire service Ensure ac...

Page 13: ...al container Even if ash appears cold red hot embers may be concealed and could easily start a fire or cause injury 6 6 Multi fuel grate except Ecoboiler Wood The grate in your Ecoboiler stove compris...

Page 14: ...It is then these objects such as the chimney breast hearth etc which heat the surrounding air in the room 7 2 Hot Water Your stove also has a boiler jacket integrated into the rear of the stove This...

Page 15: ...w sits square to the body if not repeat the previous step If the fire door needs to be raised please follow the instructions below 1 When the appliance is cold open the fire door so that it is at righ...

Page 16: ...your Arada stove We appreciate that we have given you a lot of information to read but we hope it has been clear and helpful and that you are now able to enjoy the full benefits of your stove However...

Page 17: ...a red oxide colouring will demonstrate the over heating of internal parts body paint which has turned dusty white is also indicative of such use The following guarantee periods shall apply in respect...

Page 18: ...ere flue draw readings have not been made to confirm a suitability of the flue The manufacturer s decision as to whether this condition has been satisfied shall be final 7 The guarantee does not cover...

Page 19: ...ifications have been made to the stove which have been carried out by anyone other than Arada or its authorised representatives or approved dealers 14 All guarantee periods commence on the date of pur...

Page 20: ...Date of issue 19 7 2016 BK560 Rev 10 All Arada Stoves are manufactured in the UK Arada Ltd The Fireworks Weycroft Avenue Axminster Devon EX13 5HU United Kingdom www aradastoves com T 44 0 1297 632050...