
Dry Stove Installation Guide
•
Ensure a Carbon Monoxide alarm is fitted. This must be between 1m to 3m
from the appliance, and approximately 150mm below the ceiling level.
•
A fireguard conforming to BS 8423:2002 should be used in the presence of
children or infirm people.
•
A notice plate should be provided containing information on the
performance characteristics of the hearth, fireplace, flue or chimney.
•
Explain the following to the customer:
How to operate the riddling mechanism and air control lever.
The importance of an adequate air supply to the room.
The importance of regularly having the chimney swept / inspected.
That a protective glove should be used when operating the stove.
How changes in the weather can effect the performance of the stove.
Using the correct fuels.
BK545 Rev06
10