![ARA Pharmaceuticals First Canadian Health SPIRIT Owner'S Booklet Download Page 12](http://html1.mh-extra.com/html/ara-pharmaceuticals/first-canadian-health-spirit/first-canadian-health-spirit_owners-booklet_2962443012.webp)
22 www.arapharma.com
www.arapharma.com 23
Comparing the Control Solution Test Results
The test result of each control solution should be within the
range printed on the label of test strip vial. Repeat the control
solution test if the test result falls outside of this range. Out of
range results may occur in the following factors:
If results continue to fall outside the range printed on the
test strip vial, the test strip and meter may not be working
properly. Do not use your system and contact First Canadian
Health sales representative.
• When the control solution bottle was not
shaken well,
• When the meter, test strip, or the control
solution were exposed to high or low
temperatures,
• When the first drop of the control solution
was not discarded or the tip of the bottle
was not wiped clean,
• When the meter is not functioning properly.
• When the control solution is past the
expiration date printed on the bottle,
• When the control solution is past its
discard date (the date the bottle was
opened plus three (3) months),
• When the control solution is contaminated.
Situations
Do This
Repeat the
control solution
test by referring
to the “Notes” on
page 19.
Discard the used
control solution
and repeat the
test using a new
bottle of control
solution.
Caution:
To avoid infection when drawing a sample, use a
lancet only once, and:
• Do not use a lancet that has been used by others.
• Always use a new sterile lancet.
• Keep the lancing device clean.
Note:
Repeated puncturing at the same sample site may
cause pain or skin calluses (thick hard skin). Choose a different
site each time you test.
Using the Lancing Device
You will need a lancing device in order to collect a blood sample.
You may use the lancing device included in the First Canadian
Health SPIRIT Blood Glucose Monitoring System or any other
medically approved lancing device.
Adjustable Tip
Lancet Holder
Sliding Barrel
Release Button
Ejection System
Lancet
• The lancing device is for use by a single user only and should
not be shared with anyone.
• Use a soft cloth or tissue to wipe the lancing device. If
necessary, a small amount of alcohol on a soft cloth or
tissue may be used.