Model 2000W1000D
28
Rev B
2.6.6.15
Operating Hours (Power On)
Query to get the Power On operating hours.
Syntax:
OHP?
Parameters:
None
Response Format:
OHP=x<LF>
Where:
x
=
0
to
100000
Units are Hours. Values can be up to six digits in length. Leading zeros are read as
spaces.
Example:
To find out the Power On operating hours, send the following query.
OHP?<LF>
Response:
OHP=<space><space><space>428<LF>
(The system has spent 428 Hours in a Power On state)
2.6.6.16
AC Power-On Defaults
Default settings that are applied at AC mains power-on can be changed by adding the following prefix to
select commands.
Syntax:
DEFAULT:
Compatible commands:
Level Adjust
LEVEL:GAIN
LEVEL:DET
(Not available on all models)
LEVEL:THR
(Not available on all models)
LEVEL:RESP
(Not available on all models)
Mode Select
MODE:MANUAL
(Not available on all models)
MODE:PULSE
(Not available on all models)
MODE:ALC<space>INT
(Not available on all models)
MODE:ALC<space>EXT
(Not available on all models)
NOTES:
1.
Use the command
DEFAULT:FACTORY
to reset all applicable settings back to their factory defaults.
2.
All applicable defaults can be queried, except
DEFAULT:FACTORY
, by adding a ? character in place
of the setting parameter.
3.
If the ALC Lockout Feature (not available on all models) is engaged, the default ALC values set with this
command will not be used.