Model 100S1G6AB
14
Rev A
2.4.6.8
Machine State
This query reads the RF gain, detector gain, ALC threshold, and ALC response time of the amplifier.
Syntax:
MSB?
Parameters:
None
Query only (always requires a ? character)
Response Format:
RF<space>GAIN=x,
DT<space>GAIN=x,
THRES=x,
RESP=y<LF>
Value(x):
For RF Gain, Detector Gain, and ALC Threshold:
0
= Minimum
100
= Maximum
Value(y):
For Response Time:
0
= Minimum
7
= Maximum
Response Time Setting
Time (mS)
0
1
1
5
2
10
3
30
4
100
5
1000
6
3000
7
3000
Example:
To get the machine state, send the following command:
MSB?<LF>
Response:
RF<space>GAIN=100,DT<space>GAIN= 50,THRES= 75,RESP=1 <LF>
(RF gain is 100%, Detector Gain is 50%, ALC Threshold is 75%, and ALC Response Time is set to 5mS)
Summary of Contents for 100S1G6AB
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 100S1G6AB 2 Rev A ...
Page 36: ...Model 100S1G6AB 20 Rev A ...
Page 40: ...Model 100S1G6AB 24 Rev A ...
Page 50: ...Model 100S1G6AB 34 Rev A ...
Page 52: ......