Model 100S1G6AB
Rev A
11
2.4.6.1
Power On/Off
This command controls the power on/off state of the amplifier.
Syntax:
POWER:x
Parameters:
State(x):
OFF
= power off
ON
= power on
Response Format: None (No query for this command)
Example:
To turn the power on, send the following command:
POWER:ON<LF>
To turn the power off, send the following command:
POWER:OFF<LF>
2.4.6.2
RF On/Off
This command controls the RF on/off state of the amplifier.
Syntax:
RF:x
Parameters:
State(x):
OFF
= power off
ON
= power on
Response Format: None (No query for this command)
Example:
To turn the RF on, send the following command:
RF:ON<LF>
To turn the RF off, send the following command:
RF:OFF<LF>
2.4.6.3
Reset Faults
This will clear all faults, if possible.
Syntax:
RESET
Parameters:
None
Response Format: None (No query for this command)
Example:
To clear any faults, send the following command:
RESET<LF>