Model 60/40S1G18B
Rev A
13
2.4.6.3
Reset Faults
This will clear all faults, if possible.
Syntax:
RESET
Parameters:
None
Response Format: None (No query for this command)
Example:
To clear any faults, send the following command:
RESET<LF>
2.4.6.4
Level Adjust
This command sets the RF gain of the 60/40S1G18B.
Syntax:
LEVEL:xy
Parameters:
Parameter(x):
GAIN
= RF Gain
Value(y):
For RF Gain:
0
= Minimum
100
= Maximum
Response Format: None (No query for this command)
Example:
To set the RF Gain to minimum, send the following command:
LEVEL:GAIN0<LF>
To set the RF Gain to 50%, send the following command:
LEVEL:GAIN50<LF>