![AR 10045879 Operating And Service Manual Download Page 49](http://html1.mh-extra.com/html/ar/10045879/10045879_operating-and-service-manual_2962290049.webp)
Model 250U1000
Rev A
31
4.3.7
Low or No Power Output (RF Test) (Schematic Diagram No.
10041561 and 10042997)
NOTE: The DC Tests specified in Section 4.3.8 should be completed before conducting the RF tests specified
in the following sections.
1.
The Model 250U1000’s typical gain response at -20 dBm input and 0 dBm input is shown in Figure 4-1
and Figure 4-2. The actual gain may vary considerably from that shown in Figure 4-1 but should
be ≥
53
dBm across the band at 0dBm input.
Figure 4-1. Typical Response at -20dBm Input
Figure 4-2. Typical Response at 0 dBm Input