Model 250U1000
Rev A
17
2.4.6.7
State
Query to find the state of the 4U MPC.
Syntax:
STATE?
Parameters:
None
Response Format:
STATE=<space>xyza<LF>
Where:
x, y, z
, and
a
are each an ASCII character representing a hexadecimal character.
They can be 0 to 9 or A to F.
Each hexadecimal character represents a 4-bit binary number. This 4-bit number is a bit
pattern which contains information about the state of the 4U MPC. The definitions of
these bit positions can be found in the table below.
NOTE: Bits labeled NOT USED may be read as a bit state of 1 or 0
Table 2-5. States
BIT STATE
BIT
POSITION
BIT DESCRIPTION
0
1
NOTES:
x
0
(NOT USED)
1
(NOT USED)
2
(NOT USED)
3
REMOTE CONTROL
DISABLED
ENABLED
Response to Toggle Switch
position
y
0
POWER STATUS
OFF
POWER ON
1
STANDBY STATUS
OFF
STANDBY
Also known as RF OFF
2
OPERATE STATUS
OFF
OPERATE
Also known as RF ON
3
FAULT STATUS
OFF
FAULT
EXISTS
z
0
(NOT USED)
1
(NOT USED)
2
(NOT USED)
3
(NOT USED)
a
0
(NOT USED)
1
(NOT USED)
2
(NOT USED)
3
(NOT USED)
Example:
To read the state, send the following query.
STATE?<LF>
Response:
STATE=<space>8300<LF>
(Remote Mode, Power On, RF OFF)
Summary of Contents for 10045879
Page 2: ......
Page 4: ......
Page 6: ......
Page 21: ...Page 3 250U1000 250 watts CW 100kHz 1000MHz Graphs...
Page 22: ...Page 4 250U1000 250 watts CW 100kHz 1000MHz Graphs...
Page 24: ......
Page 44: ...Model 250U1000 26 Rev A...
Page 52: ...Model 250U1000 34 Rev A...
Page 54: ......