AR 10037990 Operating And Service Manual Download Page 7

INSTRUCTIONS FOR SAFE OPERATION 

 

Revised 0517 

 

Observe the following safety guidelines to help ensure your own 

personal  safety and to help protect your equipment and working 

environment from potential damage. 

INTENDED USE 

This equipment is intended for general laboratory use in generating, 

controlling, and measuring levels of electromagnetic Radio Frequency 

(RF) energy. Ensure that the device is operated in a location which will 

control the radiated energy and will not cause injury or violate 

regulatory levels of electromagnetic interference. 

SAFETY SYMBOLS 

These symbols may appear in your user manual or on equipment. 

 

This  symbol is marked on the equipment when it is 

necessary for the user to refer to the manual for 

important safety information.  

The caution symbol denotes a potential hazard. 

Attention must be given to the statement to prevent 

damage, destruction, or harm. 

 

Dangerous voltages are present. Use extreme care.

 

 

 

Indicates a terminal intended for connection to an 

external conductor for protection against electrical 

shock in case of a fault, or the terminal of a protective 

earth (ground) electrode. 

 

Indicates invisible laser radiation–do not view directly 

with optical instruments. 

 

Indicates frame or chassis ground connection terminal. 

 

Indicates alternating current. 

 

Indicates this product must not be disposed of with your 

other household waste. 

 

Indicates that the marked surface and adjacent surfaces 

can attain temperatures that may be hot to the touch. 

 

EQUIPMENT SETUP PRECAUTIONS 

Review the user manual and become familiar with all 

safety markings and instructions.  Protection provided by 

the equipment may be impaired if used in a manner not 

specified by AR RF/Microwave Instrumentation (AR). 

 

Follow all lifting instructions specified in this document. 

 

Place the equipment on a hard, level surface. 

 

Do not use the equipment in a wet environment, for example, near 

a sink, or in a wet basement. 

 

Position your equipment so that the power switch is easily 

accessible.  

 

Leave 10.2 cm (4 in) minimum of clearance on all vented sides of 

the equipment to permit the airflow required for proper 

ventilation. Do not restrict airflow into the equipment by blocking 

any vents or air intakes. Restricting airflow can result in damage 

to the equipment, intermittent shut-downs or safety hazards. 

 

Keep equipment away from extremely hot or cold temperatures 

to ensure that it is used within the specified operating range.  

 

While installing accessories such as antennas, directional 

couplers  and field probes,  take care to avoid any exposure to 

hazardous RF levels.  

 

Ensure that nothing rests on your equipment’s cables and that the 

cables are not located where they can be stepped on or tripped 

over. 

 

Move equipment with care; ensure that all casters and/or cables 

are firmly connected to the system. Avoid sudden stops and 

uneven surfaces. 

BEFORE APPLYING POWER 

Your AR equipment may have more than one power supply cable. Use 

only approved power cable(s). If you have not been provided with a 

power cable for the equipment or for any AC-powered option intended 

for the equipment, purchase a power cable that is approved for use in 

your country. The power cable must be rated for the equipment and for 

the voltage and current marked on the equipment’s electrical ratings 

label.  

Incorrectly installing or using an incompatible line 

voltage may increase the risk of fire or other hazards. To 

help prevent electric shock, plug the equipment and 

peripheral power cables into properly grounded electrical 

outlets. These cables are equipped with three-prong plugs to help 

ensure proper grounding. Do not use adapter plugs or remove the 

grounding prong from a cable. 
Do not modify power cables or plugs. Consult a licensed electrician or 

AR trained service technician for equipment modifications. Always 

follow your local/national wiring rules.  

Do not operate the equipment if there is physical 

damage, missing hardware, or missing panels. 

 

SAFETY GROUND 

This equipment is provided with a protective earth 

terminal. The mains power source to the equipment must 

supply an uninterrupted safety ground of sufficient size to 

attach  wiring terminals, power cord, or supplied power 

cord set. 

DO NOT USE this equipment if this protection is impaired. 

 

 

Summary of Contents for 10037990

Page 1: ...Operating and Service Manual 250T6G18 Model 10037990 Part Number Serial Number 160 School House Road Souderton PA 18964 215 723 8181 Fax 215 723 5688 www arworld us...

Page 2: ......

Page 3: ...lowing European directives Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU Supplementary Information Safety EN 60215 1 1989 EN 61010 1 2010 EMC EN 61000 6 2 2005 EN61000 6 4 2007 Year Mark A...

Page 4: ......

Page 5: ...n folgenden Minimalwerte der Schirmd mpfung und Filterung in den unterschiedlichen Leistungsklassen empfohlen Hochfrequenzleistung min Schirmd mpfung 100 Watt 50 dB 101 1000 Watt 60 dB 1001 10 000 Wat...

Page 6: ......

Page 7: ...clearance on all vented sides of the equipment to permit the airflow required for proper ventilation Do not restrict airflow into the equipment by blocking any vents or air intakes Restricting airflow...

Page 8: ...a assembly may be heavy requiring two persons to lift Use caution when installing or removing unit Follow all equipment setup and lifting instructions specified in this document Ensure connectors are...

Page 9: ...von 10 2 cm 4 in auf allen bel fteten Seiten des Ger ts ein um eine ausreichende Luftzirkulation zu gew hrleisten Beintr chtigen Sie den Luftstrom des Ger ts nicht indem Sie L ftungs ffnungen oder de...

Page 10: ...allen in diesem Dokument angegebenen Anweisungen zur Anbringung Stellen Sie sicher dass alle Anschl sse f r den beabsichtigten Betrieb geeignet sind Informationen zu den Anschl ssen erhalten Sie im Be...

Page 11: ...tilation Ne limitez pas le flux d air allant dans l quipement en bloquant tout vent ou entr e d air La restriction du flux d air peut endommager l quipement causer des coupures intermittentes ou des d...

Page 12: ...dent lorsque vous installez ou retirez l unit Respectez toutes les instructions concernant l installation et le levage de l quipement indiqu es dans ce document Assurez vous que les connecteurs sont a...

Page 13: ...is voor goede ventilatie mogelijk te maken Belemmer de luchtstroom in het apparaat niet door ventilatieopeningen of luchtinlaten te blokkeren Het belemmeren van de luchtstroom kan leiden tot schade a...

Page 14: ...nstellen en optillen van de apparatuur die in dit document worden vermeld Zorg ervoor dat de connectoren geschikt zijn voor de beoogde werking De connectoren worden gespecificeerd in de gebruikershand...

Page 15: ...ions to the machine may have been made use this information only as a guide Carefully compare the unit s actual configuration and operation to the descriptions in this manual before you undertake to o...

Page 16: ...Model 250T6G18...

Page 17: ...quency with Gain set to 100 apply RF drive that will provide rated power This will help indicate if the gain or power is changing and if the traveling wave tube or pre amp needs service Record the fol...

Page 18: ......

Page 19: ...ements 9 3 2 4 AC Line Power Connections 9 3 2 5 RF Connections 10 3 2 6 Waveguide Installation 10 3 2 7 External Interlock Connector 11 3 3 Front Panel Features 12 3 4 Front Panel Display and Soft Ke...

Page 20: ...eatures 17 TABLES 3 1 Front Panel Features 12 3 2 Rear Panel Features 17 3 3 Catalog of IEEE 488 Commands 19 3 4 Catalog of Status Codes 21 3 5 Catalog of Fault Codes 21 3 6 Catalog of System State Co...

Page 21: ...ctors For bench top use the amplifier is supplied in an enclosure with integral carrying handles Primary power is 190 260 volts 50 60 Hz single phase An efficient switching power supply design provide...

Page 22: ...Model 250T6G18 2 Rev A 1 5 TEST DATA SHEET A Test Data Sheet for a specific unit is prepared at the time of manufacture and is included with the unit s copy of this manual...

Page 23: ...ing wave tube TWT microwave amplifier designed for applications where instantaneous bandwidth and high gain are required A reliable 300 watt TWT provides a conservative 250 watts minimum at the amplif...

Page 24: ...WER 190 260 VAC 50 60 Hz single phase 2 0 KVA maximum CONNECTORS RF input Type N female on rear panel RF output Type WRD 650 waveguide flange on rear panel RF output sample port Type N female on rear...

Page 25: ...he solid state preamp The solid state preamp s output drives the RF input of the TWT The RF output of the TWT is a WRD 650 for Model 250T6G18 The output is directed through a straight length of wavegu...

Page 26: ...ided by the Modulator Assembly A23684 121 The high voltage power supply consists of the following the Power Factor Correction module A23683 000 converts line voltage to DC for the high voltage switchi...

Page 27: ...es present in microwave tube amplifiers in general and with this equipment in particular Never handle the TWT leads or the high voltage connectors unless the unit has been unplugged and it has been po...

Page 28: ...k or cabinet Carefully remove the HPA from the rack or cabinet If slide rails are used depress the buttons on each slide rail to remove the unit from the rack CAUTION Never rack mount the TWTA using t...

Page 29: ...t in the unit shutting down from overtemperature conditions The TWTA dissipates approximately 1 5 kilowatts when in the operate mode 3 2 4 AC Line Power Connections AC line power connection to the TWT...

Page 30: ...at there is no possibility of damaging the load by overheating before the switch opens The TWTA may be interlocked with the switch by connecting it between pins 3 and 4 of the external interlock conne...

Page 31: ...If the amplifier shuts down because the interlock was opened it will be necessary to reset the system to return to standby see System shutdown screen in Section 3 4 In addition there is an external i...

Page 32: ...eared 3 STANDBY Push button biases grid off and turns off high voltage 4 ADJUST Rotary knob used as an input device to change values of a variety of parameters 5 EXIT Push button terminates various me...

Page 33: ...umber of informational screens are programmed It is important for the operator to be able to select the screen with the required information Screen selection is accomplished by pressing an appropriate...

Page 34: ...below Pressing S1 SET toggles between On and OFF Pressing MORE again brings up the SETUP 2 screen which allows the user to change the Auto Sleep Mode timer setting Pressing SET will change the timer...

Page 35: ...disabling this alarm In WARNINGS 3 the maximum reverse power level is set Note that these are warning levels at which the beep sounds the actual maximum reverse power level that generates a system fa...

Page 36: ...h voltage on will be enabled once again Factory Service Screens A number of screens intended for factory service and calibration are behind passwords and are not accessible to the user System Malfunct...

Page 37: ...er input connector 2 REMOTE INTERFACE Remote control connector 3 EXTERNAL INTERLOCK Connector to remote temperature switch protecting the isolator load 4 Cooling air intake 5 Cooling air outlet 6 RF I...

Page 38: ...left the factory are logged on the test data sheet Push the OPERATE push button You will now see the cathode and the collector voltages rise Verify that the grid collector and cathode voltages are nea...

Page 39: ...is a manual control for the gain adjustment as well This is a flat square single turn pot R1 CAUTION Do not adjust 20 turn pot R11 its function is to set the foldback VSWR level and it is calibrated...

Page 40: ...ut dBm dBm Pr dBm RDPRW Returns reverse power out W watts Pr W RDPOHID Returns over forward power warning setpoint dBm dBm Pohi dBm SPOHID Sets over forward power warning setpoint dBm dBm RDPOLOD Retu...

Page 41: ...oes not have remote enabled 51 Remote system is not ready to accept commands 60 Command is not allowed in current system state 901 Assert error invalid table argument 1 902 Assert error invalid calibr...

Page 42: ...LSB Heater time delay expired 5 Under forward power warning 6 Foldback active 7 MSB Inhibit mode x bit Meaning 8 LSB External inhibit 9 Interlock open 10 ALC 11 MSB not used w bit Meaning 12 LSB not...

Page 43: ...riage return where command mnemonic consists of one of any valid command found in Table 3 parameter as applicable consists of one ASCII space character followed by a number carriage return consists of...

Page 44: ...e amplifier for pulse or CW operation enter the setup menu and push MORE until reaching the last setup screen which says amplifier is set to Push SET to achieve the mode of operation desired In the pu...

Page 45: ...bleshooting the TWTA remove the TWT and substitute suitable loads to prevent damage to the TWT 4 2 UNAUTHORIZED REPAIRS CAUTION Unauthorized repairs or modification of this product during the warranty...

Page 46: ...r inlet temperature Defective blower or power supply No response when main power turned on Panel open interlock switch open Control module display does not come up unit does not beep when powered up S...

Page 47: ...Diode Cap Assembly A22818 002 the High Voltage Filter Assembly A21461 000 the Modulator Assembly A21422 101 and the Heater Supply A10010 000 are encapsulated modules and are not repairable Contact an...

Page 48: ...Model 250T6G18 28 Rev A...

Page 49: ...shoot and repair the TWTA in the field Such repairs are typically limited to replacement of modules or major components For this reason documentation pertaining to the highest levels of the system and...

Page 50: ...Model 250T6G18 30 Rev A...

Page 51: ...ON D McCLURE 1040 1041 DIM F 80 1042 DIM A 80 1050 CLEAR SCREEN 1060 INPUT INPUT COMMAND TO SEND TO POWER SUPPLY EXIT TO QUIT A 1070 IF A EXIT THEN 1130 1080 OUTPUT 701 A 1090 IF A 1 2 RD THEN GOTO 10...

Page 52: ...Model 250T6G18 32 Rev A...

Page 53: ...cover If the security label is removed and or cut the warranty of the module will be voided Vacuum tubes in the L series amplifiers traveling wave tubes in TWT amplifiers and power heads will be free...

Page 54: ......

Reviews: