![AR 10036733 Operating And Service Manual Download Page 29](http://html1.mh-extra.com/html/ar/10036733/10036733_operating-and-service-manual_2962278029.webp)
Model 30S1G6
2.4.5.6
State
Query to find the state of the amplifier.
Syntax:
STATE?
Parameters:
None
Response Format:
STATE=<space>xyza
Where:
x
,
y
,
z
, and
a
are each an ASCII character representing a hexadecimal character.
They can be 0 to 9 or A to F.
Each hexadecimal character represents a 4-bit binary number. This 4-bit number is a
bit pattern which contains information about the state of the amplifier. The
definitions of these bit positions can be found in the table below.
Note: Bits labeled NOT USED may be read as a bit state of 1 or 0
BIT STATE
BIT
POSITION
BIT
DESCRIPTION
0
1
NOTES:
x
0
(NOT USED)
1
(NOT USED)
2
(NOT USED)
3
REMOTE
CONTROL
DISABLED
ENABLED
Response to mode switch position
y
0
POWER STATUS
OFF
POWER ON
1
(NOT USED)
2
(NOT USED)
3
FAULT STATUS
OFF
FAULT EXISTS
z
0
(NOT USED)
1
(NOT USED)
2
(NOT USED)
3
(NOT USED)
a
0
(NOT USED)
1
(NOT USED)
2
(NOT USED)
3
(NOT USED)
Example:
To read the state of the amplifier, send the following query:
STATE?<LF>
Response:
STATE= 8100<LF> (Remote Mode and Power On)
Rev A
13
Summary of Contents for 10036733
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 30S1G6 2 Rev A...
Page 34: ...Model 30S1G6 18 Rev A...
Page 44: ......