Model 30S1G6
6
Rev A
2.2 AMPLIFIER FRONT AND REAR PANELS
Figure 2-1 shows the front panel of the Model 30S1G6 Broadband Microwave Amplifier. Figure 2-2 shows
the rear panel of the Model 30S1G6 Broadband Microwave Amplifier.
Figure 2-1. Model 30S1G6 Front Panel
Figure 2-2. Model 30S1G6 Rear Panel
2.3 LOCAL
OPERATION
2.3.1 Power-up
Sequence
1.
Connect the input signal to the unit’s RF INPUT connector. The input signal level should be 0dBm
maximum.
2.
Connect the load to the unit’s RF OUTPUT connector.
3.
Set the REMOTE/LOCAL switch to LOCAL.
4.
Check to see that the MAIN POWER switch on the unit’s rear panel is set to the 1 (on) position.
5.
Press the POWER switch: the front panel vacuum fluorescent display (VFD) should read
POWER ON
,
when power is applied.
NOTE:
The amplifier changes state each time the POWER switch is depressed—if the unit is on when
the POWER switch is depressed, it will turn off; if the unit is off when the POWER switch is
depressed, it will turn on.
6.
Adjust the amplifier’s gain by rotating the GAIN knob.
NOTE: The amplifier requires 30 minutes of
warm-up time to avoid any gain or power drift.
7.
In the event of a fault, press the FAULT/RESET switch; if the fault does not clear, refer to section 4.3
Troubleshooting
of this manual.