Model 800A3B
Rev D
22
2.6.6.8
State
Query to find the state of the amplifier.
Syntax:
STATE?
Parameters:
None
Response Format:
STATE=<space>xyza<LF>
Where:
x, y, z
, and
a
are each an ASCII character representing a hexadecimal character. They
can be 0 to 9 or A to F.
Each hexadecimal character represents a 4-bit binary number. This 4-bit number is a bit
pattern which contains information about the state of the amplifier. The definitions of
these bit positions can be found in the table below.
NOTE: Bits labeled NOT USED may be read as a bit state of 1 or 0
BIT STATE
BIT
POSITION
BIT DESCRIPTION
0
1
NOTES:
x
0
PULSE STATUS
OFF
PULSE
1
(NOT USED)
2
(NOT USED)
3
REMOTE CONTROL
DISABLED
ENABLED
Response to key-switch
position
y
0
POWER STATUS
OFF
POWER ON
1
STANDBY STATUS
OFF
STANDBY
Also known as RF OFF
2
OPERATE STATUS
OFF
OPERATE
Also known as RF ON
3
FAULT STATUS
OFF
FAULT
EXISTS
z
0
KEYLOCK INHIBIT
OFF
INHIBITED
Response to key-switch
position
1
(NOT USED)
2
(NOT USED)
3
(NOT USED)
a
0
MODE MANUAL
DISABLED
ENABLED
1
MODE PULSE
DISABLED
ENABLED
2
MODE ALC
INTERNAL
DISABLED
ENABLED
3
MODE ALC
EXTERNAL
DISABLED
ENABLED