2.6.6.3
Reset Faults
This will clear all faults, if possible.
Syntax:
RESET
Parameters:
None
Response Format: None (No query for this command)
Example:
To clear any faults, send the following command:
RESET<LF>
2.6.6.4
Level Adjust
This command sets the RF Gain, ALC Detector Gain, ALC Threshold, and ALC Response Time.
Syntax:
LEVEL:xy
Parameters:
Parameter(x):
GAIN
= RF Gain
Value(y):
0
= Minimum
100
= Maximum
Response Format: None (No query for this command)
Example:
To set the RF Gain to minimum, send the following command:
LEVEL:GAIN0<LF>
To set the RF Gain to 50%, send the following command:
LEVEL:GAIN50<LF>
2.6.6.5
Identity
Query to identify the amplifier.
Syntax:
*IDN?
Parameters:
None
Query only (always requires a ? character)
Response Format:
f,m,n,<LF>
Where:
f
= manufacturer
m
= model designation
n
= firmware revision
Example:
To get the identity of the amplifier, send the following command:
*IDN?<LF>
Response:
AR-RF/MICROWAVE-INST,
MODEL
,1.0<LF>
Summary of Contents for 10036390
Page 2: ......
Page 4: ......
Page 16: ......
Page 44: ...Model 800A3B Rev D 28...
Page 50: ...Model 800A3B Rev D 34...