Model 1000W1000G
14
Rev A
2.3.1
RF GAIN Control
The RF GAIN control is used to adjust the input attenuator of the preamplifier-leveler module. This control
simply adjusts the output power level for a fixed input power level.
To adjust the RF Gain, press the Select button from the Main Menu and then press the RF Gain button in the
subsequent menu. Adjust the value using the adjust knob. Please note that the display panel is limited in
resolution compared to the control signals, which are generated and sent to the leveler electronics module.
2.4 INPUTS AND OUTPUTS
The input and output connectors described in the following sections are located on the unit’s front or rear
panels; refer to the Front and Rear Panel Features drawings (Figure 2-1, Figure 2-2).
2.4.1
RF Input
This Type N connector is the RF input to the amplifier. It should be connected to a RF signal generator or
sweep generator.
2.4.2
RF Output
This Type 7/16 female connector is the RF output of the amplifier. For proper connection to the RF output
connector a torque of 221 in-lbs. (24.97 N-m) shall be used.
CAUTION:
Do not connect or disconnect any loads or cables from the amplifier’s RF
Output when the amplifier is in the Operate mode. Dangerous voltages
that could cause serious injury to the user exist at the RF Output when the
amplifier is under power.
2.4.3
IEEE-488, USB, and RS-232 Interfaces
The Model 1000W1000G’s remote interfaces allow remote control, via a computer, of all amplifier functions
(except for the Keylock Switch position) that can be controlled from the front panel. When the amplifier is in
the Remote mode (as determined by the position of the Keylock Switch), a special Remote display is shown
(see Figure 2-3). Front panel controls are deactivated, except for the Keylock Switch, which can be rotated to
LOCAL or INHIBIT in order to prevent remote control commands from being executed.
Refer to Section 2.6 for information on remote operation of the amplifier.
2.4.4
Safety Interlock Connector
Located on the left side of the rear panel, as viewed from the rear, are the remote interface connectors and
safety interlock connectors. The 15-pin D-sub miniature female safety interlock connector provides two
separate interlock loops. Pins 1 and 8 are used for situations where the amplifier can be left on, but forced
into STANDBY mode. This interlock is called Inhibit Interlock. Pins 10 and 14 are used for situations that
demand the safest possible condition, with the AC power to all main circuits disconnected. This interlock is
called AC Interlock. Both loops must be closed, or jumpered, for normal operation.
Summary of Contents for 1000W1000G
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ......
Page 22: ...Model 1000W1000G 4 Rev A...
Page 25: ...Page 3 1000W1000G 1000 watts CW 80MHz 1000MHz Graphs...
Page 26: ...Page 4 1000W1000G 1000 watts CW 80MHz 1000MHz Graphs...
Page 28: ......
Page 66: ...Model 1000W1000G 46 Rev A...
Page 68: ...Model 1000W1000G 48 Rev A...
Page 70: ...Model 1000W1000G 50 Rev A...