3.5 REAR PANEL FEATURES
See Figure 3-4 below, and Table 3-2 for descriptions.
Figure 3-4. Rear Panel Features
Table 3-2. Rear Panel Features
Label Title
Function
1
190-260 VAC IN
AC power input cable
2
IEEE-488
Remote control connector: 24-pin hermaphrodite
3
INTAKE VENT
Cooling air intake.
4
OULET VENT
Cooling air outlet.
5
RF INPUT
Type N female connector (see NOTE)
6
FWD SAMPLE OUT
Type N female connector (see NOTE)
7
RF OUT
WRD-750 Waveguide (WRD-650 in certain configurations)
8
EXTERNAL INTERLOCK/ SWITCH CONTROL
Connector to remote temperature switch protecting the isolator or load;
Connector for optional RF switch control cable; D-sub 15-pin female
9
PULSE GATE IN
External pulse input; BNC connector
10
REV SAMPLE OUT
Type N female connector (Optional) (see NOTE)
NOTE: Units may have the following connectors located on the front panel or on the rear panel: RF INPUT,
FWD SAMPLE OUT and optional REV SAMPLE OUT. See the model specification sheet.