MAINTENANCE
The TWTA requires a minimum of routine maintenance
.
The only moving parts are the elements of switches,
relays and blowers. Preventive maintenance is recommended in Paragraph 4.3.
In the event that the TWTA needs repairs, it is recommended that the unit be returned to the factory.
However, some user service organizations may choose to perform their own corrective maintenance, and
under some circumstances returning the unit to the factory may be impractical. The highly modular
construction of the TWTA facilitates troubleshooting to the level of readily replaced subassemblies. Section 5
provides partial technical documentation to support field repairs. Nevertheless, the factory or its service
representative should be contacted before undertaking repair work on these TWTAs.
Warnings and
Cautions must be observed.
4.1 SAFETY
WARNING
WARNING:
Service work must be performed only by technicians thoroughly familiar
with the high voltages present in microwave tube amplifiers in general,
and with this equipment in particular.
Never handle the TWT leads or the high-voltage connectors unless it has
been positively established that the high-voltage filter capacitors have
been discharged to a known safe level.
CAUTION:
A malfunctioning power supply can cause damage to the TWT. If you are
troubleshooting the TWTA, remove the TWT and substitute suitable
loads to prevent damage to the TWT.
4.2 UNAUTHORIZED
REPAIRS
CAUTION:
Unauthorized repairs or modification of this product during the warranty
period may void the warranty. In the event that the TWTA malfunctions
while it is still under warranty, always contact an authorized service
representative.
4.3 PREVENTIVE
MAINTENANCE
The RF characteristics, power supply voltages and currents, and system temperatures of the TWTA should be
logged on a regular basis. Maintenance should be performed if significant deviations from the logged values
appear. For a unit still under warranty, contact an authorized service representative if impaired performance is
suspected.
The air intake filters are the only items that require routine service. The frequency of service depends on the
environment where the TWTA is used, and must be determined by inspection
Summary of Contents for 1000T2G8B
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 18: ......
Page 30: ...Model 1000T2G8B 16 Rev 3 5 REAR PANEL FEATURES Figure 3 3 Rear Panel Features...
Page 40: ...Model 1000T2G8B 26 Rev...
Page 44: ...Model 1000T2G8B 30 Rev...
Page 46: ...Model 1000T2G8B 32 Rev...
Page 50: ...Model 1000T2G8B 36 Rev...
Page 51: ...Model 1000T2G8B Rev 37 5 3 BLOCK DIAGRAM 25 28005 000 RF Combiner for L Band A28005 004...
Page 52: ...Model 1000T2G8B 38 Rev...
Page 72: ......