Model 1000T2G8B
Rev -
19
Command
Function
Units
Response
format
RDTMPTWTHPA1C
Returns TWT temp (°C), HPA1
°C
TWTHPA1C=[ ]C
RDTMPTWTHPA2C
Returns TWT temp (°C), HPA2
°C
TWTHPA2C=[ ]C
RDTMPPSHPA1F
Returns power supply temp (°F), HPA1
°F
PSHPA1F=[ ]F
RDTMPPSHPA2F
Returns power supply temp (°F), HPA2
°F
PSHPA2F=[ ]F
RDTMPPSHPA1C
Returns power supply temp (°C), HPA1
°C
PSHPA1C=[ ]C
RDTMPPSHPA2C
Returns power supply temp (°C), HPA2
°C
PSHPA2C=[ ]C
RDTWTOTF
Returns TWT overtemp warning setpoint (°F)
°F
TWTOTF=[ ]F
STWTOTF
Sets TWT overtemp warning setpoint (°F)
°F
RDTWTOTC
Returns TWT overtemp warning setpoint (°C)
°C
TWTOTC=[ ]C
STWTOTC
Sets TWT overtemp warning setpoint (°C)
°C
RDPSOTF
Returns power supply overtemp warning setpoint (°F)
°F
PSOTF=[ ]F
SPSOTF
Sets p. s. overtemp warning setpoint (°F)
°F
RDPSOTC
Returns p. s. overtemp warning setpoint (°C)
°C
PSOTC=[ ]C
SPSOTC
Sets p. s. overtemp warning setpoint (°C)
°C
RDIWOC
Returns helix overcurrent warning setpoint
mA
IwOC=[ ]
SIWOC
Sets helix overcurrent warning setpoint
mA
RDLOGIC
Returns logic state code (see Table 3-6)
Sys=[ ]
RDA
Returns gain
%
A=[ ]
SA
Sets gain
%
RDHTDREM
Returns remaining heater time delay
sec.
HTD=[ ]s
RDPOD
Returns forward power out (dBm)
dBm
Po=[ ]dBm
RDPOW
Returns forward power out (W)
watts
Po=[ ]W
RDPRD
Returns reverse power out (dBm)
dBm
Pr=[ ]dBm
RDPRW
Returns reverse power out (W)
watts
Pr=[ ]W
RDPOHID
Returns over forward power warning setpoint (dBm)
dBm
Pohi=[ ]dBm
SPOHID
Sets over forward power warning setpoint (dBm)
dBm
RDPOLOD
Returns under forward power warning setpoint (dBm)
dBm
Polo=[ ]dBm
SPOLOD
Sets under forward power warning setpoint (dBm)
dBm
RDPOHIW
Returns over forward power warning setpoint (W)
watts
Pohi=[ ]W
SPOHIW
Sets over forward power warning setpoint (W)
watts
RDPOLOW
Returns under forward power warning setpoint (W)
watts
Polo=[ ]W
SPOLOW
Sets under forward power warning setpoint (W)
watts
RDPRHID
Returns over reverse power warning setpoint (dB)
dBm
Prhi=[ ]dBm
SPPRHID
Sets over reverse power warning setpoint (dBm)
dBm
RDPRHIW
Returns over reverse power warning setpoint (W)
watts
Prhi=[ ]W
SPRHIW
Sets over reverse power warning setpoint (W)
watts
RDHTRAUTOOFF
Returns heater to auto off delay
hours
SHTRAUTOOFF
Sets heater auto off delay (see Table 3-9)
*IDN?;
Returns the product model number
[ ]
*STA?;
Returns status string (see Table 3-7)
[ ]
*STB?;
Returns status string (see Table 3-8)
[ ]
Summary of Contents for 1000T2G8B
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 18: ......
Page 30: ...Model 1000T2G8B 16 Rev 3 5 REAR PANEL FEATURES Figure 3 3 Rear Panel Features...
Page 40: ...Model 1000T2G8B 26 Rev...
Page 44: ...Model 1000T2G8B 30 Rev...
Page 46: ...Model 1000T2G8B 32 Rev...
Page 50: ...Model 1000T2G8B 36 Rev...
Page 51: ...Model 1000T2G8B Rev 37 5 3 BLOCK DIAGRAM 25 28005 000 RF Combiner for L Band A28005 004...
Page 52: ...Model 1000T2G8B 38 Rev...
Page 72: ......