![AR 10006896 Operating And Service Manual Download Page 37](http://html1.mh-extra.com/html/ar/10006896/10006896_operating-and-service-manual_2962263037.webp)
Model 500T2G8
Rev E
25
Table 3-8. *STB?; Response Codes
(The command
*STB?;
causes the TWTA to send a string containing an operational state code consisting of 2
ASCII characters representing hex digits. The response is in the form
STATUS:[x][y][eol]
where the hex
values of
[x]
and
[y]
are formed as shown below)
y bit
Meaning
0 (LSB)
Power status; always 1(power on)
1
Standby status; 0 if not in standby, 1 if in standby
2
Operate status; 0 if not in operate, 1 if in operate
3 (MSB)
Fault status; 0 if no fault, 1 if fault exists
x bit
Meaning
4 (LSB)
Mode switch; always 1 (reset)
5
Blank switch; always 1 (off)
6
Blank status; always 0 (off)
7 (MSB)
Not used; always 0
Table 3-9. Catalog of Heater Auto Off Time Delay Codes
Argument
Meaning
0
0.5 hour heater auto off time delay
1
1.0 hour heater auto off time delay
2
1.5 hour heater auto off time delay
3
2.0 hour heater auto off time delay
4
2.5 hour heater auto off time delay
5
3.0 hour heater auto off time delay
Command syntax is in this form:
<command mnemonic> <parameter> <carriage return>
Where:
<command mnemonic> consists of one of any valid command found in Table 3-3.
<parameter> (as applicable) consists of one ASCII space character followed by a number.
<carriage return> consists of an ASCII carriage return.
All commands are case sensitive.
The system will return parameter values, fault codes, and status codes regardless of whether remote is
enabled. The parameter value is returned as a string of 20 characters or less, consisting of a label,
=
, and a
value. For example, outputting the command
RDEF
to the TWTA would result in the TWTA sending back
the string
Ef=6.03
(assuming the heater voltage is 6.03 volts). Units are usually not returned; see Table 3-3
for the units.
If remote is not enabled, set commands and commands to the system logic (i. e., OPERATE; or STANDBY;
or RESET;) will not be accepted.
It is recommended that the
RDSTAT
command be used to provide the host program with a report on how a
command was processed.
Summary of Contents for 10006896
Page 2: ......
Page 4: ......
Page 8: ...Model 500T2G8...
Page 10: ......
Page 18: ......
Page 40: ...Model 500T2G8 28 Rev E...
Page 44: ...Model 500T2G8 32 Rev E...
Page 46: ...Model 500T2G8 34 Rev E...
Page 50: ...Model 500T2G8 38 Rev E...
Page 52: ...Model 500T2G8 40 Rev E...
Page 66: ...Model 500T2G8 54 Rev E...
Page 68: ......