MAINTENANCE
Page 9
ROUTINE CHECKS
Regularly the user should perform a basic check to verify if
the water filter is functioning correctly, on the basis of the
following control points:
1.
Check settings of electronic control panel.
2.
Check water composition before/after water filter.
3.
Check drain line from control valve; there shouldn’t be
any water flow (unless water filter is in regeneration).
4.
Check water filter and surrounding area; there
shouldn’t be any water leakages.
BYPASSING THE WATER FILTER
Occasionally it may be necessary to put the unit
hydraulically in bypass, i.e. to isolate it from the water
distribution system; f.e.:
in case of an urgent technical problem;
when it is not necessary to supply treated water to the
house/application (irrigation,...).
WITH FACTORY BYPASS (optional)
Picture 7.a
SERVICE
POSITION
= inlet valve to water filter is OPEN
= outlet valve from water filter is OPEN
Picture 7.b
BYPASS
POSITION
= inlet valve to water filter is CLOSED
= outlet valve from water filter is CLOSED
Picture 7.c
MAINTENANCE
POSITION
= inlet valve to water filter is OPEN
= outlet valve from water filter is CLOSED
WITH 3-VALVE BYPASS SYSTEM (not included)
Picture 8.a
SERVICE
POSITION
= bypass valve is CLOSED
= inlet valve to water filter is OPEN
= outlet valve from water filter is OPEN
Picture 8.b
BYPASS
POSITION
= bypass valve is OPEN
= inlet valve to water filter is CLOSED
= outlet valve from water filter is CLOSED
Picture 8.c
MAINTENANCE
POSITION
= bypass valve is OPEN
= inlet valve to water filter is OPEN
= outlet valve from water filter is CLOSED
SANITIZING THE WATER FILTER
If the power supply to the water filter is disconnected for a
longer period of time, we recommend, when the power
supply is re-established, to manually initiate a complete
regeneration.
Summary of Contents for Oxydizer
Page 10: ...HYDRAULIC FLOW DIAGRAMS O2xydizer Page 10 SERVICE BACKWASH PURGE ...
Page 11: ...HYDRAULIC FLOW DIAGRAMS O2xydizerPRO Page 11 SERVICE BACKWASH AIR INTAKE PURGE ...
Page 13: ...ELECTRICAL WIRING DIAGRAMS Page 13 position switches power lead drive motor key pad ...
Page 15: ...Page 15 ...
Page 16: ...EXPLODED VIEW SYSTEM Page 16 ...
Page 18: ...EXPLODED VIEW TIMER HEAD Page 18 ...
Page 20: ...EXPLODED VIEW VALVE BODY O2xydizer Page 20 ...
Page 22: ...EXPLODED VIEW VALVE BODY O2xydizerPRO Page 22 ...
Page 25: ...Page 25 ...
Page 26: ......
Page 27: ......
Page 28: ......