START-UP 

 

Page 6 

PRESSURIZING

 

 

1.

 

Make sure the bypass system is in 'bypass' position. 

2.

 

Make sure the electronic controller of the water  filter 
is in service mode.  

3.

 

Open the mains water supply. 

4.

 

Open  a  cold  treated  water  faucet  nearby  the  water 
filter and let the water run for a few minutes  until all 
air  is  purged  and  all  foreign  material  that  may  have 
resulted from the installation is washed out; close the 
tap. 

5.

 

Gently  pressurize  the  water  filter,  by  putting  it  into 
service: 

 

factory bypass: 

1.

 

open the 'outlet' valve; 

2.

 

slowly open the 'inlet' valve.  

 

3-valve bypass: 

1.

 

close the 'bypass' valve; 

2.

 

open the 'outlet' valve; 

3.

 

slowly open the 'inlet' valve. 

6.

 

After  2-3  minutes,  open  a  cold  treated  water  faucet 
nearby  the  water  filter  and  let  the  water  run  until  all 
air  is  purged  from  the  installation  and  the  filter 
medium  is  properly  rinsed;  it  is  normal  for  the  rinse 
water  to  show  some  discoloration;  let  the  water  run 
until the rinse water is clear; close the tap. 

7.

 

Check the water filter and all hydraulic connections for 
leaks. 

 

 

O

2

xydizer

PRO

  only:  during  the  passage  through  the 

compressed  air  chamber,  the  treated  water  will  get 
highly  oxygenated.  As  a  consequence  it  may  become 
slightly non-transparent (milky appearance) when it flows 
from the tap into a glass. This is totally harmless for the 
quality of the treated water and will disappear rapidly if 
the water is left standing for a moment! 

 

ELECTRONIC CONTROL PANEL 

 
8.

 

Program the electronic controller. 

 

PERFORM REGENERATION 

 

 

We strongly recommend to postpone the execution of 

this  'start-up'  regeneration  by  24  hours.  The  filter 
medium needs sufficient time to absorb water and reach 
its  normal  service  weight.  If  the  regeneration  is 
performed  too  soon,  the  filter  medium  may  be  pushed  
against  the  top  distributor  during  the  backwash  cycle, 
possibly  resulting  in  loss  of    filter  medium  or  damage  to 
the top distributor. 

 

9.

 

Manually initiate a regeneration, by pressing the 

scroll

 

 button repeatedly until the display shows:  

 
 
 

10.

 

Leave  the  water  filter  in  this  position;  the  countdown 
timer will countdown to 0 sec and start a regeneration. 

 
 

 

 

Regen in 10 sec 

Summary of Contents for Oxydizer

Page 1: ... 2012 Aquion Inc TM EN Oxydizer Rev2012 08 T TE EC CH HN NI IC CA AL L M MA AN NU UA AL L Fe Mn H2S WATER FILTER ...

Page 2: ...l panel Page 7 Maintenance Page 9 Hydraulic flow diagrams O2xydizer Page 10 Hydraulic flow diagrams O2xydizerPRO Page 11 Troubleshooting Page 12 Electrical wiring diagrams Page 13 Default parameter settings Page 14 Exploded view System Page 16 Exploded view Timer head Page 18 Exploded view Valve body O2xydizer Page 20 Exploded view Valve body O2xydizerPRO Page 22 Technical Specifications Page 24 ...

Page 3: ...ly be undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the water filter make sure to check it for any externally visible damage do not install or use when damaged Use a hand truck to transport the water filter To prevent accident or injury do not hoist the water filter over your ...

Page 4: ...sure the performance may be affected negatively if installed on a well verify that the well pump is powerful enough to provide sufficient flow rate for the regeneration check water pressure regularly install a pressure reducer ahead of the water filter if necessary OPERATING TEMPERATURE min 4 max 38 C do not install the water filter in an environment where high ambient temperatures e g unvented bo...

Page 5: ...ter inlet of water filter untreated water outlet of water filter treated water house application treated water 1 Install the 3 valve bypass system 2 Screw the connection kit with nuts onto the in out ports on the control valve make sure to install the gasket seals Tighten the nuts firmly by hand 3 Connect the 3 valve bypass system to the nipples on the in and out port of the control valve 4 Connec...

Page 6: ...se the tap 7 Check the water filter and all hydraulic connections for leaks O2xydizer PRO only during the passage through the compressed air chamber the treated water will get highly oxygenated As a consequence it may become slightly non transparent milky appearance when it flows from the tap into a glass This is totally harmless for the quality of the treated water and will disappear rapidly if t...

Page 7: ...ilure the display will show the message If powering off on the water filter doesn t solve this problem professional service is required SERVICE MODE In service mode the display shows the time of day and remaining number of days before the next regeneration REGENERATION MODE In regeneration mode the display shows the remaining regeneration time and the remaining cycle time The control valve can be ...

Page 8: ... of day 3 Press the scroll button again the display will show Press the up or down button to set the number of days between regenerations The absorption capacity of the O2xydizer systems mainly depends on the daily water usage and the Iron Manganese content in the water many other factors may also have a significant impact on the absorption capacity Therefore it is recommend to regenerate the syst...

Page 9: ...ASS optional Picture 7 a SERVICE POSITION inlet valve to water filter is OPEN outlet valve from water filter is OPEN Picture 7 b BYPASS POSITION inlet valve to water filter is CLOSED outlet valve from water filter is CLOSED Picture 7 c MAINTENANCE POSITION inlet valve to water filter is OPEN outlet valve from water filter is CLOSED WITH 3 VALVE BYPASS SYSTEM not included Picture 8 a SERVICE POSITI...

Page 10: ...HYDRAULIC FLOW DIAGRAMS O2xydizer Page 10 SERVICE BACKWASH PURGE ...

Page 11: ...HYDRAULIC FLOW DIAGRAMS O2xydizerPRO Page 11 SERVICE BACKWASH AIR INTAKE PURGE ...

Page 12: ...ation Faulty electrical supply Verify electrical service fuse transformer Defective PCB Replace PCB Defective drive motor Replace drive motor Regeneration frequency not programmed Program regeneration frequency Loss of water pressure Build up of impurities in pressure tank Clean filter medium and control valve increase regeneration frequency Plugged lower and or upper distributor Verify that distr...

Page 13: ...ELECTRICAL WIRING DIAGRAMS Page 13 position switches power lead drive motor key pad ...

Page 14: ...Page 14 Model O2xydizer O2xydizer PRO Filter medium quantity Cuft Ltr 1 28 2 56 1 28 2 56 Interval days 4 4 4 4 Cycle 1 BACKWASH min 10 10 10 10 Cycle 2 AIR INTAKE min 0 0 10 15 Cycle 3 PURGE min 2 2 2 2 Regen 0 00 0 00 0 00 0 00 ...

Page 15: ...Page 15 ...

Page 16: ...EXPLODED VIEW SYSTEM Page 16 ...

Page 17: ...iser tube assembly to be cut to length 4 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 5 287 166 Top distributor 6a 2400TF JN AUX Control valve O2xydizer 1 Cuft 2400TF JQ AUX Control valve O2xydizer 2 Cuft 6b 2400TF J5N AUX AIR Control valve O2xydizerPRO 1 Cuft 2400TF J5Q AUX AIR Control valve O2xydizerPRO 2 Cuft 7 568 303 6 Connection kit 3 4 BSP male Recommended Spare Part ...

Page 18: ...EXPLODED VIEW TIMER HEAD Page 18 ...

Page 19: ...or assy 2x 9 28 245 4 Cable clamp 10 71502 Strain relief power lead 11 72261 Drive motor 12 568 227 2 Worm 13 19 48 Retaining ring 14 70965 Switch cam 15 568 386 Bracket micro switches 16 568 310 Gear switch cam 17 15 184 7 Locking screw switch cam 18 15 173 12 Screw micro switches 2x 19 72451 Micro switch assy 20 71679 Cable set drive motor 21 15 102 Screw PCB 2x 22 72703 Printed Circuit Board 23...

Page 20: ...EXPLODED VIEW VALVE BODY O2xydizer Page 20 ...

Page 21: ...Gasket 15 413 62 Spring float valve 16 568 270 4 Float valve 17 568 274 5 Injector green 18 186 118 O ring plug small 19 541 273 Plug small 20 541 254 Spring clip plug small 21 570 251 Gasket riser 22 568 334 Riser insert 23 185 214 1 O ring riser tube 24 185 337 1 O ring tank 25 541 232 Adapter ring 26 15 207 12 Screw adapter ring 2x 27 568 216 3 Packing gland nut 28 185 211 1 O ring packing glan...

Page 22: ...EXPLODED VIEW VALVE BODY O2xydizerPRO Page 22 ...

Page 23: ...green 18 186 118 O ring plug small 19 541 273 Plug small 20 541 254 Spring clip plug small 21 570 251 Gasket riser 22 568 334 Riser insert 23 185 214 1 O ring riser tube 24 185 337 1 O ring tank 25 541 232 Adapter ring 26 15 207 12 Screw adapter ring 2x 27 568 216 3 Packing gland nut 28 185 211 1 O ring packing gland nut 29 186 115 O ring worm drive shaft 2x 30 568 208 2 Worm drive shaft 31 14 43 ...

Page 24: ...PRO Filter medium quantity Cuft Ltr 1 28 2 56 1 28 2 56 Recommended max service flow m 3 hr 2 1 1 1 6 1 1 1 6 Nominal backwash flow flow to drain Ltr min 23 30 23 30 Rinse water usage per regeneration Ltr 272 364 352 444 2 continuous service flow rates higher up to x2 short period peak flow rates are possible Dimensions and weights Model O2xydizer O2xydizer PRO Filter medium quantity Cuft Ltr 1 28...

Page 25: ...Page 25 ...

Page 26: ......

Page 27: ......

Page 28: ......

Reviews: