START-UP
Page 6
PRESSURIZING
1.
Make sure the bypass system is in 'bypass' position.
2.
Make sure the electronic controller of the water filter
is in service mode.
3.
Open the mains water supply.
4.
Open a cold treated water faucet nearby the water
filter and let the water run for a few minutes until all
air is purged and all foreign material that may have
resulted from the installation is washed out; close the
tap.
5.
Gently pressurize the water filter, by putting it into
service:
factory bypass:
1.
open the 'outlet' valve;
2.
slowly open the 'inlet' valve.
3-valve bypass:
1.
close the 'bypass' valve;
2.
open the 'outlet' valve;
3.
slowly open the 'inlet' valve.
6.
After 2-3 minutes, open a cold treated water faucet
nearby the water filter and let the water run until all
air is purged from the installation and the filter
medium is properly rinsed; it is normal for the rinse
water to show some discoloration; let the water run
until the rinse water is clear; close the tap.
7.
Check the water filter and all hydraulic connections for
leaks.
O
2
xydizer
PRO
only: during the passage through the
compressed air chamber, the treated water will get
highly oxygenated. As a consequence it may become
slightly non-transparent (milky appearance) when it flows
from the tap into a glass. This is totally harmless for the
quality of the treated water and will disappear rapidly if
the water is left standing for a moment!
ELECTRONIC CONTROL PANEL
8.
Program the electronic controller.
PERFORM REGENERATION
We strongly recommend to postpone the execution of
this 'start-up' regeneration by 24 hours. The filter
medium needs sufficient time to absorb water and reach
its normal service weight. If the regeneration is
performed too soon, the filter medium may be pushed
against the top distributor during the backwash cycle,
possibly resulting in loss of filter medium or damage to
the top distributor.
9.
Manually initiate a regeneration, by pressing the
scroll
button repeatedly until the display shows:
10.
Leave the water filter in this position; the countdown
timer will countdown to 0 sec and start a regeneration.
Regen in 10 sec
Summary of Contents for Oxydizer
Page 10: ...HYDRAULIC FLOW DIAGRAMS O2xydizer Page 10 SERVICE BACKWASH PURGE ...
Page 11: ...HYDRAULIC FLOW DIAGRAMS O2xydizerPRO Page 11 SERVICE BACKWASH AIR INTAKE PURGE ...
Page 13: ...ELECTRICAL WIRING DIAGRAMS Page 13 position switches power lead drive motor key pad ...
Page 15: ...Page 15 ...
Page 16: ...EXPLODED VIEW SYSTEM Page 16 ...
Page 18: ...EXPLODED VIEW TIMER HEAD Page 18 ...
Page 20: ...EXPLODED VIEW VALVE BODY O2xydizer Page 20 ...
Page 22: ...EXPLODED VIEW VALVE BODY O2xydizerPRO Page 22 ...
Page 25: ...Page 25 ...
Page 26: ......
Page 27: ......
Page 28: ......