ELECTRONIC CONTROL PANEL
EN - English
Page 8
Picture 8
symbol
button
function
SCROLL
to advance to the next
parameter
UP
to increase the value of the
parameter
DOWN
to decrease the value of the
parameter
POWER-UP
After power-up the display will show the installed software
version for a period of 5 seconds; f.e.:
POWER FAILURE
In the event of a power failure, the program will remain
stored in the NOVRAM® during an undefined period,
while
the SuperCap will maintain the correct time of day during a
period of several hours; consequently, in case of prolonged
power failure, the time of day might not be maintained; if this
happens, the time of day will be reset to 8:00 when the power
supply is re-established, while the indication will
flash
,
indicating that the time of day needs to be set.
When the power failure occurs during the execution of an
automatic regeneration, the appliance will immediately
return to the service mode; when the power supply is re-
established, the appliance will resume the regeneration.
TIMER FAILURE
In the event of a timer failure, the display will show the
message:
If powering off/on the appliance
doesn’t solve this problem,
professional service is required.
MAINTENANCE REMINDER
Only available if the maintenance reminder function has
been activated and programmed by your supplier!
Once the maintenance interval is reached, the display will
intermittently show the message:
While the appliance will continue to operate normally, it is
recommended to have preventive maintenance performed
by a professional.
SERVICE MODE
In
service mode
the
display shows the time of day and the
remaining capacity:
REGENERATION MODE
In
regeneration mode
the
display shows the actual
regeneration cycle and, where relevant, the total remaining
regeneration time and remaining cycle time:
The appliance can be
reset to service mode
at any time by
pressing the
scroll
button, as such manually advancing it
through the regeneration cycles.
CHECKING THE FLOW METER
In case of water usage, the remaining capacity counter in the
service display will count back per unit, i.e. per litre. This way
the correct functioning of the water meter can be verified.
MANUAL REGENERATION
It is possible to manually initiate an immediate regeneration
or a delayed regeneration (at the preprogrammed time of
regeneration).
1.
Press the
scroll
button; the display will show:
If the control panel is left in this position, the
countdown timer will countdown to 0 sec and
start an
immediate regeneration
.
To cancel this mode, press the
scroll
button before
the countdown timer has reached 0 sec; the display
will show:
If the control panel is left in this position,
a
delayed
regeneration
will be started
at the indicated
preprogrammed time of regeneration
.
To cancel this mode, press the
scroll
button; the
control panel will return to the service mode.
Service Required
BRINE FILL
REGEN PENDING
EZ3P5f EZ3PB r14
Rgn:XXX CycY:ZZZ
8:01 1000L -
Regen in 10 sec
Regen @ 2:00
Maintenance Now
Summary of Contents for ECOPERLA slimline SLI-BBS-ECO
Page 100: ...BG Български Стр 100 ...
Page 110: ......
Page 111: ......
Page 113: ... 2015 erie water treatment PP SLI CS_BBS_MMX Rev2015 12 r 1 2 a 2 b 3 a 3 b ...
Page 114: ... 2015 erie water treatment PP SLI CS_BBS_MMX Rev2015 12 4 a 4 b 5 6 7 ...
Page 115: ... 2015 erie water treatment PP SLI CS_BBS_MMX Rev2015 12 r 8 a r 8 b 9 a 9 b r 9 c ...
Page 116: ... 2015 erie water treatment PP SLI CS_BBS_MMX Rev2015 12 r 10 a 10 b 10 c r 11 a r 11 b ...