4. Open the pure water tank cover on the equipment, put the
watered cup at the water filler and pour a proper amount of
purified water or distilled water.
5. Add water and wait for 10 minutes, then open the drain
port at the back of the equipment, empty the water tank,
plug the silicone plug,and tighten the drain cap;
6. Put the watered cup at the water filler of equipment again,
add bottled purified water or distilled water in the equipment
at about the middle level of perspective window;
7.Insert the power adapter in the power outlet of the
equipment and the other end in the mains supply socket;
8.Insert the nasal suction pipe
9.Keep pressing "Power" for 2s to turn on the equipment;
press "Time" to set the working time of equipment and click
"Start" to start the equipment to produce hydrogen.
Wearing method of nasal suction pipe
The nasal suction pipe shall be worn as per the method
in the right figure and the other end is inserted in the
hydrogen outlet of humidification bottle.
When to drain water
1. For the first use, soak the new equipment in water for 10 minutes and then
drain water;
2.When the equipment indicates low water level or abnormal water quality in
the water tank, drain residual waste water in the water tank and add new
purified water;
3.When the equipment indicates full water, drain some water till the full water
indicator turns white;
4.When the equipment is used for 14 days or not used for over 14 days, add
pure water to clean the whole waterway.
Drainage method
1. Place the water container below the drain outlet.
2.Unscrew the drain outlet nut.
3. Take out the silica gel plug
4.After the water tank is emptied, plug the silica gel plug
again and tighten the drain nut.
Instructions for Installation and Use
Satisfactory purified water is requried
To ensure the normal operation of equipment, please purchase bottled
distilled water or purified water (bottled water with mineral water and purified
water labels) in advance. To prolong the service life of the equipment,
distilled water and deionized water are preferably recommended.
For Example:
Watsons distilled water
First class high purity
ionized water for
laboratory use
C'estbon purified
water for drinking
●
Tap water should not be used.
●
Water produced by household water purifier should not be used.
●
Mineral water or natural water on the market should not be used.
●
Equipment failure caused by incorrect addition of non-conforming
water source will result in warranty disqualification.
Operating steps for the first use
1. Install the humidification bottle clamp on the equipment
with a screw.
2.Open the humidification bottle cover and then add drinking
water to the high water level in the humidification bottle.
(To cool the hydrogen add ice water.)
Tips: Add water to the low water level to effectively lower
the noise of bubble blasting.
3.Insert the nasal suction pipe in the air outlet of humidification
bottle, connect the air inlet of humidification bottle and
hydrogen outlet of equipment with a short pipe and then
put the humidification bottle in the fixing clamp.
(Note: The humidification bottle has separate air inlet
and outlet. Please do not install them reversely.)
High water line
Low water line
03
04