AquaTools AT8230 Owner'S Manual Download Page 7

7

Disassembly:

1. Stop the pump.
2. Close isolation valves to prevent flooding. 
3. Open air release valve on top of filter tank to release all pressure from inside

of tank.

NOTICE: 

Make sure that waste water disposal complies with local codes

and ordinances.

4. Remove drain plug and drain all water from tank.
5. Remove Posi-Lok™ ring as follows:

a. Press safety latch (below the ring) toward the tank to release it (see 

Figure 4).

b. Hold latch in the release position and rotate ring COUNTERCLOCKWISE

to remove.  If ring is difficult to turn, tap gently with a rubber mallet to
overcome initial resistance.

NOTICE: 

DO NOT use screwdriver or bladed instrument that may damage

shell surfaces to pry tank shells apart.

6. Separate upper and lower tank shell halves using tabs on bottom of 

Posi-Lok™ ring. Insert tab into slot located at tank joint and twist ring to pry
shell halves apart. See Figures 5 and 6.

7. Remove O-ring from upper tank shell.  Inspect for cuts, cracking, deforma-

tion or signs of wear; replace if necessary. 

NOTICE:

To avoid strain or damage, allow filter module to drain before lift-

ing it out of the tank.

SAFETY LATCH  (See Figure 7)

The purpose of the safety latch is to hold the Posi-Lok™ ring in the locked po-
sition. If the latch is damaged, replace it as follows:
1. Press down on the small catch behind the safety latch and press or tap the

latch out of the “Tee” slot in the tank (see Figure 7).

2. Snap the new latch into position.

NOTICE: 

DO NOT operate the filter if the safety latch is damaged or will

not hold the Posi-Lok™ ring in the locked position.

Assembly:

1. Inspect and clean the tank, ring threads and O-ring groove. Replace dam-

aged parts as necessary.

2. Install the filter by placing the port in the bottom of the filter cartridge over

the tank outlet port. Push down firmly to seal.

3. Ensure that the air bleed assembly on top of the module is clean and prop-

erly mounted.

NOTICE:

Lubricate O-ring only with the silicone grease provided or equiv-

alent, as other lubricants may cause the ring to swell.  DO NOT lubricate
Posi-Lok™ ring or threads on lower tank shell as this may collect grit and
make removal difficult.

4. Install the O-ring in the upper tank shell O-ring groove.  Be sure that the 

O-ring is clean and not twisted.

5. Push the upper tank shell into the lower tank shell to compress the O-ring.
6. Place the Posi-Lok™ ring squarely over the tank shell threads and rotate

COUNTERCLOCKWISE until the ring falls into the slots; then rotate
CLOCKWISE until securely latched.

7. Follow instructions in the “Initial Startup” section of this manual.

2152 1195

Figure 5 – Insert ring tab in slot in
filter body.

Figure 6 – Roll ring to one side to
loosen upper tank half.

RELEASE

RELEASE

Small
Catch

Figure 7 – Safety Latch

Summary of Contents for AT8230

Page 1: ...erica 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 2002 Printed in U S A AT339 Rev 4 30 02 This manual should be furnished to the end user of this filter...

Page 2: ...ternal source of pressurized water 2 Use equipment only in a pool or spa installation 3 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment...

Page 3: ...locked in place before operating filter Maintain pressure gauge in good working order Replace a damaged gauge immediately Cleaning interval is based on pressure rise not on length of time filter is o...

Page 4: ...PLD70 AT8230 AT8236 Table 1 Recommended DE Manufacturers Johns Manville Celite 545 GREFCO Inc Decalite 4200 Eagle Picher Minerals Inc Celatom Table 2 Filter Specifications AT8230 AT8236 Filter Area sq...

Page 5: ...plastic pipe it will cause the pipe to crack Do not use sealant on unions assemble them dry and hand tight Support pipe independently to prevent strains on filter Fittings restrict flow for best effic...

Page 6: ...nd the upper tank shell Inspect and clean the O ring and all sealing surfaces Relubricate the O ring NOTICE Lubricate O ring only with the silicone grease provided or equiva lent as other lubricants m...

Page 7: ...lows 1 Press down on the small catch behind the safety latch and press or tap the latch out of the Tee slot in the tank see Figure 7 2 Snap the new latch into position NOTICE DO NOT operate the filter...

Page 8: ...down module Be sure to dispose of spent chemicals according to all applica ble codes and waste disposal ordinances Use a soft stream nozzle to minimize flying water and spray Risk of fire or explosio...

Page 9: ...o explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping NOTICE Protect the filter from freezing...

Page 10: ...thoroughly see Page 8 C Water is chemically out of balance consult pool professional D Excessive air in filter non precoated areas may plug Vent air from tank and check for pump suc tion pipe leaks C...

Page 11: ...424 9 2 x 1 1 2 Pipe reducer 2 U78 820P 10 Pressure gauge 1 15060 0000T 10A Pressure gauge screen 1 WC8 72D 11 Air bleed assembly 1 24800 0122 12 Filter module AT8230 1 27002 0030S 12 Filter module AT...

Page 12: ...t to negligence misappli cation improper installation or maintenance or other cir cumstances which are not in AquaTools direct control Full warranty coverage is in effect for one year after instal lat...