background image

6

Hazardous pressure.
Can cause severe 
injury or major 
property damage 
from tank blow up

Release all pressure
and read instructions
before working on filter.

INITIAL START-UP

Be sure pump is OFF before starting procedure.

Do not operate these filters at more than 50 PSI (345 kPa) under any

circumstances!

To prevent serious damage to the element fabric, NEVER run

your DE filter without a diatomaceous earth precoat!

1. Securely lock Posi-Lok™ ring in place by rotating ring CLOCKWISE until it

“clicks” past the safety latch (see Figure 3). Stop turning as soon as the ring
clicks past the latch. The ring may feel slightly loose, but it will tighten up
when pump is on and filter is under pressure.

2. Fill trap on pump with water.
3. Open air release valve on top of filter.
4. Open isolation valves.
5. Start pump to purge air from system.
6. When steady stream of water comes from air release valve, close the valve.

NOTICE:

Leaking around the Posi-Lok™ ring may indicate that the ring is

not fully locked.  In this case, proceed as follows:

A. Stop the pump, close the isolation valves, and open the air release valve

to release any pressure within the filter. 

B. Remove the drain plug and drain all water from the filter.
C. Push down on the top of the filter to fully seat the upper tank shell.
D. Rotate the Posi-Lok™ clockwise until it locks behind the safety latch

(see Figure 3). 

E. If the ring was already locked, remove it and the upper tank shell.

Inspect and clean the O-ring and all sealing surfaces. Relubricate the
O-ring.

NOTICE:

Lubricate O-ring only with the silicone grease provided or equiva-

lent, as other lubricants may cause the ring to swell.  DO NOT lubricate 
Posi-Lok™ ring or threads on lower tank shell as this may collect grit and
make removal difficult.

7. To prepare precoat slurry, mix diatomaceous earth (DE) and water. Use four

pounds of DE for Model AT8236; use six pounds of DE for Model AT8230.
DO NOT use more DE than recommended.

NOTICE:

Using more than the recommeded amount of DE will clog the fil-

ter. Using less than the recommended amount will give an uneven precoat
and shorten the lifespan of the element.

8. Empty slurry slowly into skimmer to precoat filter element with an even fil-

tering precoat.

After filter is operating, record filter pressure gauge reading in owner's manual
for future use.

NOTICE: 

When installed on a new pool, after approximately 48 hours of op-

eration disassemble filter and clean out plaster dust , construction debris, etc.
(see “Module Cleaning Procedure", Page 8).

FILTER DISASSEMBLY/
ASSEMBLY PROCEDURE

Hazardous pressure. Before disassembling filter:

1. STOP PUMP.
2. CLOSE isolation valves.
3. OPEN air release valve and drain fitting.
4. WAIT until all pressure is released and water drained from filter tank and

system before loosening Posi-Lok™ Ring.

Depress Safety Latch
to unscrew Posi-Lok™

RELEASE

RELEASE

Figure 4 – Depress safety latch to
unscrew Posi-Lok™ Ring.

RELEASE

RELEASE

Latch

2149 1195

Tab

Figure 3 – Rotate Posi-Lok™
Ring until tab locks behind the
safety latch.

Summary of Contents for AT8230

Page 1: ...erica 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 2002 Printed in U S A AT339 Rev 4 30 02 This manual should be furnished to the end user of this filter...

Page 2: ...ternal source of pressurized water 2 Use equipment only in a pool or spa installation 3 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment...

Page 3: ...locked in place before operating filter Maintain pressure gauge in good working order Replace a damaged gauge immediately Cleaning interval is based on pressure rise not on length of time filter is o...

Page 4: ...PLD70 AT8230 AT8236 Table 1 Recommended DE Manufacturers Johns Manville Celite 545 GREFCO Inc Decalite 4200 Eagle Picher Minerals Inc Celatom Table 2 Filter Specifications AT8230 AT8236 Filter Area sq...

Page 5: ...plastic pipe it will cause the pipe to crack Do not use sealant on unions assemble them dry and hand tight Support pipe independently to prevent strains on filter Fittings restrict flow for best effic...

Page 6: ...nd the upper tank shell Inspect and clean the O ring and all sealing surfaces Relubricate the O ring NOTICE Lubricate O ring only with the silicone grease provided or equiva lent as other lubricants m...

Page 7: ...lows 1 Press down on the small catch behind the safety latch and press or tap the latch out of the Tee slot in the tank see Figure 7 2 Snap the new latch into position NOTICE DO NOT operate the filter...

Page 8: ...down module Be sure to dispose of spent chemicals according to all applica ble codes and waste disposal ordinances Use a soft stream nozzle to minimize flying water and spray Risk of fire or explosio...

Page 9: ...o explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping NOTICE Protect the filter from freezing...

Page 10: ...thoroughly see Page 8 C Water is chemically out of balance consult pool professional D Excessive air in filter non precoated areas may plug Vent air from tank and check for pump suc tion pipe leaks C...

Page 11: ...424 9 2 x 1 1 2 Pipe reducer 2 U78 820P 10 Pressure gauge 1 15060 0000T 10A Pressure gauge screen 1 WC8 72D 11 Air bleed assembly 1 24800 0122 12 Filter module AT8230 1 27002 0030S 12 Filter module AT...

Page 12: ...t to negligence misappli cation improper installation or maintenance or other cir cumstances which are not in AquaTools direct control Full warranty coverage is in effect for one year after instal lat...