background image

11

ABOUT MAINTENANCE AND CARE

Hazardous suction. Stop pump before

attempting to clean pool cleaner. 

• Keep skimmer basket and pump strainer basket clean

and free of debris.

• If cleaner jams with large debris (leaves, sticks, etc.),

try cleaning debris first from bottom of unit. If this
doesn’t clear unit, remove top swivel assembly (turn
1/4 turn) and clear the debris from the top.

• Remove the pool cleaner from the pool before super

chlorinating (shocking) or chemical balancing. Wait at
least four hours after the chemical procedure before
reinstalling the cleaner.

• Make sure that the cleaner’s brush bristles don’t

become deformed during storage. Store the unit so
that it doesn’t sit on the bristles and so that nothing
compresses them.

• If possible, do not coil the hose. Remove the hose from

the cleaner when removing the cleaner from the pool.
Store the hose flat and straight.

• Periodically examine bristles and vacuum skirt for

wear or distortion. Replace if necessary. See
"Assembly", Page 9.

• If necessary to remove oscillator, see "Disassembly",

Page 8.

• Don’t store the cleaner with the hose connected to the

cleaner body or with the hose coiled. To do so will
cause the hose to take a set or kink over a period of
time. When reinstalled in the pool, the hose will tend
to stay coiled and will cause the cleaner to malfunc-
tion.

• If the hose has taken a set, uncoil it as far as possible

without damaging it and lay it out in the sun for sev-
eral hours to straighten itself. Once it has relaxed and
straightened out, store it laid out flat and straight (no
coiling) if possible. If no storage area is available that
will allow this, coil the hose as loosely as possible and
expect to have to let it straighten for a while before
using the cleaner again.

• Make sure the lift brush is retracted during storage or

else that the cleaner is supported such that the lift
brush is not taking any of the cleaner’s weight. If the
lift brush is down during storage and the cleaner rests
on it, the brush bristles will collapse over time and the
cleaner will no longer turn during operation as it was
designed to do.

HOSE STORAGE

OK, Not Recommended: 

Hose is

disconnected from cleaner and
loosely coiled (no sharp bends).

Wrong: 

Storing cleaner with hose

connected will damage hose and
void the hose warranty.

Best:

Hose stored correctly – laid

out straight, not connected to
cleaner.

Summary of Contents for AT5800

Page 1: ...tand all warnings and safety information on inside cover of manual ABOUT INSTALLATION Please use the convenient water resistant Installation Instructions card INDEX About Safety 2 About Your Pool and...

Page 2: ...imouts or to work under a solar cover It was also not designed to do initial cleanup for a new pool or when opening your pool for the season Suction entrapment injury and drown ing hazard If your pool...

Page 3: ...ump Step 4 Adjust valves for vacuuming Figure 4 Decide on the vacuum connection you are going to use either a skimmer or a dedicated wall fitting and adjust the pump valves if your system has valves t...

Page 4: ...Each pool s hydraulic system and vacuum con nections are different Be sure you have installed the white plastic vacuum regulator before you fine tune the system This not only regulates vacuum but also...

Page 5: ...e of air To eliminate this slightly open the main drain valve to supplement the water intake The cleaner may slow down a bit when you change the suction Skimmer connection Some pool owners remove the...

Page 6: ...ng Vacuum regulator should be installed in all situations If the cleaner moves very slowly or not at all indicating low vacu um in the system see Troubleshooting Guide Page 7 The regulator includes tw...

Page 7: ...running and submerged If the turning brush does not move to the down position within 2 minutes call Customer Service at 1 800 752 0183 4 The cleaner was not designed to work under solar covers If you...

Page 8: ...le as a unit 6 Remove the set screw short gear shaft and gears Figure 15 do not lose the gears off of the shaft 7 With a small screwdriver such as a jeweler s screw driver a pencil or a pen point depr...

Page 9: ...llator chamber cap and clip it in place 6 Install the rubber vacuum skirt on the cleaner with the word OUTSIDE showing Start at the large pin on the back of the cleaner head See Figure 22 and work aro...

Page 10: ...Oscillator Assembly Kit Incl Key 17 AT5803 Ratchet Assembly not sold separately 19 Center Brush Kit Set of 2 AT5113 4 Vacuum Hose Extension 1 pkg AT5819 20 Vacuum Hose 1 pkg AT5821 8 Vacuum Hose Exte...

Page 11: ...hose connected to the cleaner body or with the hose coiled To do so will cause the hose to take a set or kink over a period of time When reinstalled in the pool the hose will tend to stay coiled and...

Page 12: ...ct to negligence misap plication improper installation or maintenance or other circumstances which are not in AquaTools direct control Full warranty coverage is in effect for one year after instal lat...

Reviews: